LC
-
52DH77E/RU/S
4 – 14
[2] LED flashing specification at the time of the error
Display method
• Refer to Table 1.
• Make the OPC LED flash using the [MENU] key on the remote control since the display for service persons is identified by the number of flashings
(once to 5 times).
Even if the [MENU] key is pressed again, it does not return to the display for customers (only the power LED flashes).
• After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the adjustment process screen.
LED flashing method
• Synchronize the phases of the power LED and OPC LED.
• If the LEDs have different number of flashings, adjust the flashing cycle to that where the LED flashes more times.
Table 1. Concrete flashing pattern
* 1: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
* 2: If the boot section is abnormal, there is no flashing (flashing disabled).
Item
For customers
For service persons
Cause
Power
OPC
Power
OPC
Inverter/Lamp system failure
Red flashes once
Off
Red flashes once
Flashes once
Lamp error
Power PWB failure (Power
failure, etc.)
Red flashes once
Off
Red flashes once
Flashes once
AC_DET error
Flashes twice
UR+13.5V error
Flashes 3 times
D3.3V error
Flashes 5 times
Panel power supply error
Main PWB failure
Green flashes once
Off
Green flashes once
Flashes once
Initial communication error
(Communication failure, etc.)
Flashes twice
Start-up confirmation commu-
nication error
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
Others
Green flashes twice
Off
Green flashes twice
Flashes once
Temperature error
Flashes twice
Sync error
Flashes 3 times
Notification from the main
microprocessor (*1)
VerUP executing
Orange flashes once
Off
Orange flashes once Off
Version upgrading
VerUP succeeded
Power green/OPC flash alternately
Power green/OPC flash alternately
Version upgrade succeeded
VerUP failed
Green/Red flash
alternately
Off
Green/Red flash
alternately
Off
Version upgrade failed
System
Red flashes 3 times
Off
Red flashes 3 times
Off
Mounting discrimination
connector unplugged
ROM data failure
Green/Red flash
alternately
Off
Green/Red flash
alternately
Off
Start-up after failing version
upgrade (*2)
<Flashing example for customers>
Power
<Flashing example for service persons>
Power
OPC
(Displayed by the
specific operation)
300ms
300ms
1500ms
300ms
1500ms
300ms
Содержание LC-52DH77E/RU/S
Страница 56: ...LC 52DH77E RU S 6 3 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit Side B ...
Страница 62: ...LC 52DH77E RU S 7 3 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 2 ...
Страница 63: ...LC 52DH77E RU S 7 4 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 3 ...
Страница 64: ...LC 52DH77E RU S 7 5 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 4 ...
Страница 65: ...LC 52DH77E RU S 7 6 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 5 ...
Страница 66: ...LC 52DH77E RU S 7 7 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 6 ...
Страница 67: ...LC 52DH77E RU S 7 8 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 7 ...
Страница 68: ...LC 52DH77E RU S 7 9 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 8 ...
Страница 69: ...LC 52DH77E RU S 7 10 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 9 ...
Страница 70: ...LC 52DH77E RU S 7 11 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 10 ...
Страница 71: ...LC 52DH77E RU S 7 12 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 11 ...
Страница 74: ...LC 52DH77E RU S 7 15 M E M O ...
Страница 97: ...LC 52DH77E RU S ...