LC-32LE345M
5 – 4
6. Factory setting
AC power is plug off after shipment setting is done.
CAUTION: Do not plug on again after shipment setting is done. If do, please re-do the shipment setting. Do not off with remote control.
Adjustment item
Adjustment condition
Adjustment procedure
Factory setting
AC power off to exit the fac-
tory setting.
1) Enter the adjustment process mode.
2) Move the cursor to [ Factory Init ] on page 2/10.
3) Press "ENTER" to execute.
1) User setting
2) Channel data (e. g. broadcast frequencies)
3) Manufacturer’s option settings
4) Password data
5) Setting values are set based on model destination
[ Factory setting with adjustment process mode ]
4) After a while "OK" display appears and background colour is green,
the setting is completed .
The followings are initialized to factory setting