4
INSTALLATION MANUAL
208/240 VOLT CONNECTION INSTRUCTIONS
The range can be set for 208V or 240V. The voltage setting for your
range is pre-set at 240V from the factory. Follow these steps to
change the voltage setting.
1
Locate the voltage switch on the lower back side of the
range.
2
Remove the screw and rotate the switch plate 180˚ as indicated
in the Figure 3.
3
Reinsert the switch plate and replace screw as indicated
in Figure 4. The voltage setting is indicated by the visible
marking.
POWER CORD CONNECTIONS
4-WIRE CONNECTION INSTRUCTIONS-FIGURE 8
Before wiring the range, review the suggested power source location
drawing in Figure 2. If connecting to a 4-wire electrical system for a
new branch-circuit or mobile home use a 4-wire connection.
1
Follow the power supply kit manufacturerʼs Installation
Instructions supplied with the strain relief clamp and install.
See Figure 7.
2
Insert the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block.
IMPORTANT
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
3
You must disconnect the ground strap. Remove the factory
installed ground screw and plate to release the copper ground
strap from the frame of the range. Cut and discard the copper
ground strap and plate. KEEP the ground screw.
4
Connect the green ground wire lead with the eyelet to the frame
of the range with the ground screw using the same hole in the
frame where the ground screw was originally installed. See
Figure 8.
5
Make sure all screws are tightened securely and replace the
rear access cover. See Figure 6.
3-WIRE CONNECTION INSTRUCTIONS
For existing installations ONLY, refer to Figure 9.
1
Follow the power supply kit manufacturerʼs Installation
Instructions supplied with the strain relief clamp and install.
See Figure 7.
2
Insert the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 7.
IMPORTANT
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
24
0V
20
8V
180˚
screw
screw
ACCESS TO TERMINAL BLOCK
Loosen screw on rear access cover and pull down as illustrated in
Figure 6 to access terminal block wiring connection. To close, return
to original location and secure screw.
Figure 6
Figure 3
Figure 4
24
0V
20
8V
180˚
screw
screw
Figure 7
strain relief clamp
strain relief clamp
3 & 4-WIRE ELECTRICAL WALL RECEPTACLE TYPES &
RECOMMENDED MOUNTING ORIENTATION ON WALL
Figure 5A illustrates 4-wire receptacle required for new and
remodeled installations.
Figure 5B illustrates 3-wire receptacle that is allowed for existing
installations.
Figure 5A
4-wire wall receptacle (14-50R)
3-wire wall receptacle (10-50R)
Figure 5B
4-wire wall receptacle (14-50R)
3-wire wall receptacle (10-50R)