10
Before wiring
AC Circuit breaker
This breaker must be sized to handle the rated maximum output voltage and current of the inverter. (Please refer to the
Specification
section on page 23.)
Recommended AC circuit breaker:
For JH-1600E: 10 Amps / 250 V
AC
.
To wire the main utility service panel to inverter:
(1) Connect the ground wire (green and yellow) from the ground terminal in the main utility
service panel to GND (
) terminal in the inverter.
(2) Connect the L (or Line) to Line terminal in the inverter.
(3) Connect the N (or Neutral) to Neutral terminal in the inverter.
(4) Ensure all connections are correctly wired and proper torque according to values
shown in the table below.
DC cables, isolator fuse
AS per AS/NZS 5033
Wire Size (mm
2
)
Torque
In-lb
Nm
Up to 4
12
1.3