background image

ENGLISH

Tab

(blue)

E-7

2

1

3

4

5

2

I

nstall the filters

Place the HEPA Filter into the 

main unit.

Do not install the filter backwards or the 

unit will not operate properly.

Insert  the  Filter  Support’s  2    bottom 

tabs  (left  and  right)  into  the  small 

holes in the unit, and slide the Active 

Carbon Filter between the HEPA Filter 

and the Filter Support.

Gently push in the upper tabs (left and 

right) to lock in place.

Fill in the usage start date on the Date 

Label.

Use the date as a guide for the Filter Replace-

ment schedule.

Replace the Front Panel.

Bottom tabs

HEPA Filter

Filter Support

Active Carbon Filter

Front Panel

Place  the  Front  Panel  from  the  obliquely  up-

ward, then mount the hooks at the bottom.

Please make sure that the  HEPA 

Filter(blue) and the tab  is placed 

in proper direction.

Upper tabs

Date Label

W53E.eng.indd   9

08.11.13   3:11:27 PM

Содержание FU-W43E

Страница 1: ...harp Corporation Free standing type NEDERLANDS FRANÇAIS ENGLISH DEUTSCH AIR PURIFIER OPERATION MANUAL LUFTREINIGER BEDIENUNGSANLEITUNG PURIFICATEUR D AIR MANUEL D UTILISATION LUCHTREINIGER GEBRUIKSAANWIJZING РУССКИЙ Воздухоочиститель РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ...

Страница 2: ...result in additional odour De pending on the usage environment especially when the product is used in a condition significantly more severe than household use this odour may become strong in a shorter period than expected If the odour persist the filters should be replaced Please purchase the optional replacement filter Removable by filters pollen mite allergen viruses molds dust particles of ciga...

Страница 3: ...Plasma cluster ions This is a unique air cleaning technol ogy of the SHARP CORPORATION for breaking down and eliminating such potential allergens as the fecal matter or corpses of aerial mites 1 viruses 2 and mold and bacteria 3 suspended in the air and has been substantiated by third party organiza tions both in Japan and overseas When there is a high density of Plas macluster ions in the air the...

Страница 4: ...order to avoid a hazard Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or in very high humidity condition such as a bathroom Be cautious when cleaning the unit Strong corrosive cleansers may damage the exterior Only Sharp Authorized Service Centre should service this air purifier Contact the neares...

Страница 5: ...h as televisions radios or wave clocks Avoid a location where the sensor is exposed to direct wind The unit may not operate properly Avoid locations where curtains etc come into contact with the intake or air outlet Curtains etc may become dirty or a malfunction may occur Avoid locations where the unit is exposed to condensation due to drastic temperature changes Use under appropriate conditions b...

Страница 6: ...Washable Active Carbon Filter E 4 PART NAMES MAIN UNIT DISPLAY ILLUSTRATIVE DIAGRAM Fan Speed Indicator Lights Filter Reset Indicator Light Plasmacluster ON OFF Indicator Light Plasmacluster Ion ON OFF Button Fan Speed Button ION SHOWER Indicator Light ION SHOWER Mode Button ...

Страница 7: ...mpurities in the air at the time that the air purifier was just introduced to the room environment After a while however the base impurity rate will be adjusted to detect room air condition correctly ENGLISH Green Clean Slightly Impure Very Impure Yellow Red Air Outlet Air Inlet Rating Label Power Cord Plug Handle Dust Sensor FU W53E only Shape of plug depends on country Blue Plasmacluster ON Ligh...

Страница 8: ... filters Remove the Front Panel E 6 Be sure to remove the power plug from the wall outlet FILTER INSTALLATION Remove the Filter Support Pull the Front Panel on the lower sides and lift up 3 2 1 Front Panel 1 Push in the hooks on top then pull the Filter Support Remove the Washabe Active Carbon Filter Black and HEPA Filter White from the plastic bags Filter Support HEPA Filter Active Carbon Filter ...

Страница 9: ...een the HEPA Filter and the Filter Support Gently push in the upper tabs left and right to lock in place Fill in the usage start date on the Date Label Use the date as a guide for the Filter Replace ment schedule Replace the Front Panel Bottom tabs HEPA Filter Filter Support Active Carbon Filter Front Panel Place the Front Panel from the obliquely up ward then mount the hooks at the bottom Please ...

Страница 10: ...and HIGH for 20 minutes 10 minutes HIGH fan speed 20 minutes MEDIUM fan speed 20 minutes HIGH fan speed SILENT operation The unit will operate quietly using minimal air intake MEDIUM operation The unit will operate at a fan speed of MEDIUM MAX operation The unit will operate at a fan speed of MAX HIGH fan speed is an inter mediate speed between ME DIUM and MAX ION SHOWER Mode Button When pushing t...

Страница 11: ...on for 3 seconds The Fan Speed Indicator Lights will display the currently set sensor sensitivity level The factory setting is Standard indicated by the MED light 2 3 Press the Fan Speed Button to set the desired sensor sensitivity Refer to the diagram on the right to select the desired sensor sensitivity level Press the Power ON OFF Button Note that if the Power ON OFF Button is not pushed within...

Страница 12: ...n the unit including the sen sor and filters periodically When cleaning the unit be sure to unplug the power cord and nev er handle the plug with wet hands Electrical shock and or bodily injury may occur as a result FILTER RESET INDICATOR LIGHT The Filter RESET Indicator Light will illuminate as a reminder to perform mainte nance of the Filters and Sensors The Indicator Light will turn on after ap...

Страница 13: ...ing or folding the filter when washing 3 Dry filter completely in a well ventilated area If possible dry outdoors Dry filter in a sideways position to avoid warping of the filter The filter takes about 6 hours to dry out 4 Replace the filter in unit See E 6 Dry filter completely before replacing to prevent odours Do not operate unit without all filters properly installed CAUTION CAUTION HEPA Filte...

Страница 14: ...ions of airborne particles will cause filters to become clogged in less time Please check filters regularly and replace as needed Up to 5 years after opening Replacement Filters Model HEPA Filter 1 unit FZ W53SEF Washable Active Carbon Filter 1 unit REPLACING THE FILTERS 1 See page E 6 7 for directions on how to install the filters when replacing 2 Fill in the usage start date of the filters on th...

Страница 15: ... clicking or ticking sound is heard from the unit TROUBLESHOOTING ERROR DISPLAY LAMP INDICATION REMEDY The Silent Fan Speed Indica tor Light blinks Fan motor disconnected or abnormal Operation stops Pressing the POWER ON OFF button will reset the error dis play but if error occurs again contact the Sharp Service Cen tre The discharged air has an aroma or odour Check to see if the filters are heavi...

Страница 16: ... 3 2W 1 36m3 hour FU W43E 220 240V 50 60Hz High density Plasmacluster ion applicable floor surface High density Plasmacluster ion applicable floor surface 2 3 The applicable floor surface area is appropriate for operating the unit of maximum fan speed Applicable floor surface area indicates the space where a certain amount of dust particles can be removed in 30 minutes JEM1467 Size of a room in wh...

Страница 17: ...hich could otherwise arise due to inappropriate waste handling 2 In other Countries outside the EU If you wish to discard this product please contact your local authorities and ask for the correct method of disposal For Switzerland Used electrical or electronic equipment can be returned free of charge to the dealer even if you don t purchase a new product Further collection facilities are listed o...

Страница 18: ...Memo ...

Страница 19: ...ENGLISH ...

Страница 20: ...TINS A303KKRZ CN Printed in China 08L OSAKA JAPAN SHARP CORPORATION ...

Отзывы: