TROUBLESHOOTING
Before calling for repair, check the symptoms below for possible remedies, since the problem may
not be a malfunction of the unit.
SYMPTOM
REMEDY (not a malfunction)
The remote control does not
function
• Have the batteries depleted?
• Are the batteries inserted with correct polarity?
• Is a fluorescent lighting in the room flickering?
Odors and smoke cannot be
removed easily
• Are the filters covered with heavy dust?
The Clean sign lights up in
green even when the air is
dirty
• Is the opening of the dust sensor blocked or clogged?
• Was the air already dirty when the power plug was inserted
into the wall outlet? (Refer E-5)
The Clean sign lights up in
orange or red even when the
air is clean
• The sensitivity of the sensor becomes unstable when the
opening of the dust sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer E-12)
The cluster ion lamp remains
green (blue) and does not
change
• During the Clean mode (or Refresh mode), the cluster ion
lamp color will not change.
A sound is
heard from
the unit
Click, click
Tick, tick, tick
• This is the sound that is emitted when the unit is in
the Refresh mode.
If the sound is annoying, switch the unit to the Clean mode.
• This is the sound that is emitted when the unit is generat-
ing cluster ions.
If the sound is annoying, such as when sleeping, etc., set
the Cluster ion mode to OFF.
The discharged air smells
• The ozone generated by the cluster ion generator may have
an odor. However, the amount of ozone generated is very
little and is harmless to the human body. Furthermore, the
ozone decomposes quickly so it does not accumulate in
the room.
The unit does not operate
even when smoking ciga-
rettes
• Is the unit installed in a location that is difficult for the sen-
sors to detect cigarette smoke?
• If the odor or dust sensor openings blocked or clogged?
(In this case, clean the openings.) (Refer E-12)
SPECIFICATIONS
The applicable floor surface area is the surface area
for operating the unit in Max fan speed.
(According to Japan Electrical Manufacturers’ Asso-
ciation JEM1467)
Power supply
220-240V 50Hz
Fan speed
operation
Fan speed adjustment
Max
High
Medium
Low
Rated power consumption
39W
21W
10W
4W
Air delivery rate
240m
3
/hour
180m
3
/hour 117m
3
/hour
30m
3
/hour
Applicable floor surface
~31m
2
Cord length
2.5m
Dimensions
415mm(W)X197mm(D)X572mm(H)(W/ stand)
Weight
6.6kg
About the reduction of standby power consumption.
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product
consumes about 0.8W of standby power.
(Under this condition, the power lamp will be on) For the conservation of energy, remove the power plug
when not using the unit
E-14
Содержание FU-888SV
Страница 1: ...ENGLISH R MODEL FU 888SV ENGLISH Tabletop wall mounting type AIR PURIFIER OPERATION MANUAL ...
Страница 2: ......
Страница 31: ...ENGLISH ...
Страница 32: ...SHARP CORPORATION OSAKA JAPAN TINS A048KKRZ 02CO 1 ...