![Sharp FU-40SE-TA Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/sharp/fu-40se-ta/fu-40se-ta_service-manual_364690016.webp)
16
FU-40SE-TA
4. Special modes
Some of them are not used during servicing, and are described for reference only.
(1) Test mode
This is to test malfunctions of circuits and used to check them in mass production process.
Setting procedure: Turn the power on while holding down the ON Operation selector/OFF TIMER button, and
press the " OFF timer " button on the remote control within five seconds.
A pip sound is heard and the unit starts the test mode.
Red
Fan
OUTPUT
Quick
SIilent
Green
Green
Green
Green
Green
Orange
Green
Red
Yellow
Auto
SIilent
Median
High
Max
Tobacco
Pollen
Red
Green
Green
Green
Red
Blue
Green
Buzzer
OFF timer
Clean sign
LED
CONTROL UNIT
OPERATION MODE
No.
OPERATION
1
2
3
4
5
6
7
8
9
10
Remarks
FIilter
1h
4h
8h
Power
Cluster
POINT TO BE CHECKED
: ON
: ON,
: Flashing,
: Pip sound,
: ON or OFF,
Turn the power on while hol
ding down
the " Operation " button on
the main
unit. While holding it do
wn, press the
" OFF timer " on the remote control
(within 5 seconds).
Confirmation of EEPROM
These 8 LEDs display data of EEPROM
on the control PWB (8 bits in hexadecimal).
Check the EEPROM check sum.
NG if LEDs except specified
light up.
Press the " Operation " button on
the main unit.
Press the " Manual " button on the
remote control.
Press the " Silent " button on the
remote control.
Press the " Tobacco " button on
the remote control.
Press the " Auto " button on the
remote control.
Press the " Max " button on the
remote control.
Insert a stick from the window of
the dust sensor.
Bring the gas (of alcohol, lighter,
etc.) close to the gas sensor.
Power OFF
Revolution speed inspection
These 8 LEDs display the revolution speed
(8 bits in hexadecimal).
Check the revolution speed of the
fan motor with the LED.
For max, cigarette smoke, and
pollen, , , ,
, and are acceptable.
The clean sign changes from
green to orange.
The clean sign changes from
orange to red.
Dust sensor inspection
Odor sensor inspection
Clean sign lamp(green) lights
when 10 seconds have passed
since the power supply was
turned on.