background image

11

SPECIFICATIONS

Model

FP-A80M

Power supply

220-240 V  50-60 Hz

Fan 
Speed 
Operation

Fan Speed Adjustment

MAX

MED

LOW

Rated Power (W)

75

20

5

Air flow (m

3

/hour)

480

300

120

Noise Level (dBA)

*1

53

41

23

Standby power (W)

 

0.75

Recommended Room Size

 

 (m

2

)

*2

62

High density Plasmacluster ion

 

recommended 

room size

 

 (m

2

)

*3

34

Sensor

Dust

Filter type

HEPA

*4

 filter / Deodorizing Pre filter

Cord Length  (m)

2.0

Dimensions  (mm)

402 (W) × 245 (D) × 620 (H)

Weight (kg)

8.1

*1 • Noise level is measured based on the JEM1467 standard of the Japan Electrical Manufactures’ Association.

*2 • The recommended room size is appropriate for operating the product of maximum fan speed.

•  The recommended room size is an area in which a given amount of dust particles can be removed in 30 

minutes (according to JEM1467).

*3 •  Room size in which approximately 7000 ions per cubic centimeter can be measured in the center of the 

room when the product is placed next to a wall, is running at MED mode settings, and is at a height of 

approximately 1.2 meters from the floor.

*4 • The filter removes more than 99.97% of particles at least 0.3 microns in size (according to JEM1467).

Standby Power

When the product’s power plug is inserted in a wall outlet it consumes standby power in order to 

operate electrical circuits.

To conserve energy, unplug the power cord when the product is not in use.

FP-A80M.indd   11

FP-A80M.indd   11

2022/03/01   11:25:07

2022/03/01   11:25:07

Содержание FP-A80M

Страница 1: ...ber in this technology mark indicates an approximate number of ions supplied into air of 1 cm3 which is measured around the center of a room applicable floor area at 1 2 m height above the floor when the product is placed close to a wall at the MED mode setting FP A80M indd 1 FP A80M indd 1 2022 03 01 11 24 41 2022 03 01 11 24 41 ...

Страница 2: ... remove air suspended dust and odor but not harm ful gases for example carbon monoxide contained in cigarette smoke If the odor sources still exist it cannot completely remove the odor for example odors from construction materials and pet odors It is suggested to open the window a bit when you are smoking in order to facilitate ventilation In this case we recommend purchasing the optional replacem...

Страница 3: ...om that air is drawn through the filter system Room size 62m2 Thank you for purchasing the SHARP Air Pu rifier Please read this manual carefully Be fore using this product be sure to read the section Important Safety Instructions After reading this manual keep it in a conven ient location for future reference For your reference we recommend to keep this manual in the place where you can read at an...

Страница 4: ...t use the product if the power cord or plug is damaged or if the connection to the wall outlet is loose Periodically remove dust from the plug Do not insert fingers or foreign objects into the Air Inlet or Air Outlet When removing the power plug always hold the plug and never pull on the cord Failure to do so can cause a short circuit resulting in electrical shock or fire Be careful not to damage ...

Страница 5: ... polishing powder In addition the sensors may malfunction as a result Do not scrub the Back Panel hard during its maintenance INSTALLATION GUIDELINES Avoid locations where the sensors are exposed to direct wind Doing so can cause the product to malfunction Avoid locations where furniture fabrics or other objects can come in contact with the product and interfere with the inlet and outlet of air Av...

Страница 6: ...Operation manual BACK 1 3 4 2 7 5 6 8 9 10 1 Air Outlet 2 Air Inlet 3 Handle 4 Main Unit 5 HEPA Filter 6 Deodorizing Pre Filter 7 Dust Sensor 8 Date Label 9 Power Cord 10 Plug FP A80M indd 4 FP A80M indd 4 2022 03 01 11 24 45 2022 03 01 11 24 45 ...

Страница 7: ...dicator Light green 13 CHILD LOCK Button CHILD LOCK Indicator Light green 14 CLEAN SIGN The color changes according to the air condition 15 Plasmacluster Sign blue 16 FAN SPEED Indicator Light green 17 FAN SPEED Button 18 POWER Button Green Yellow Red Clean Very Impure 13 FP A80M indd 5 FP A80M indd 5 2022 03 01 11 24 46 2022 03 01 11 24 46 ...

Страница 8: ...lling the bottom gently towards you 2 Remove the plastic bags 3 Place the filters accordingly Keep the order of filters 4 Fix the Front Panel Fix the Front Panel by hooking it into the top of the unit Swing panel in by pushing gently until the panel snaps into place 5 Record the date when you start or replace the filters HEPA filter white Deodorizing Pre filter black Starting date of use Replaceme...

Страница 9: ...ors dust pollution level and adjusts fan speed accordingly Yellow Red Clean Very Impure ON OFF SHOWER Operation Light Control Press for 3 seconds to se lect ON OFF of the Plusmaclus ter SIGN and the CLEAN SIGN AUTO mode The air purifier operates the airflow speed automatically according to the interior pollution level detected by the sensor CHILD LOCK Press for 3 seconds to select CHILD LOCK Opera...

Страница 10: ...If it is very dirty wash it with water and dry it thoroughly CLEANING THE UNIT Dust sensor Deodorizing Pre filter Sensor cover Sensor filter MAINTENANCE Wipe with a dry soft cloth For stubborn stains or dirt use a soft cloth dampened with warm water Do not use volatile fluids and deter gents Benzene paint thinner polishing powder detergent ingredients etc may damage the unit Care Cycle Whenever du...

Страница 11: ...Please dispose the filters according to the local disposal laws and regulations HEPA filter material Filter Polypropylene Frame Polyester HEPA filter Deodorizing Pre filter Record the date when you replace the filters Deodorizing Pre filter material Deodorizer Activated charcoal Filter Polyurethane foam Frame Paper Starting date of use Replacement Filters Replace the filters when they are no longe...

Страница 12: ...d be impure at the time the unit was plugged in Unplug the unit wait one minute and plug the unit in again The Clean Sign illuminates yellow or red but the air seems clean Clean the dust sensor with a vacuum cleaner as it may be blocked or clogged Refer to page 8 The Clean Sign doesn t light on The Light Control is selected Press for 3 seconds to light on The Clean Sign lights change color frequen...

Страница 13: ...ing the product of maximum fan speed The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes according to JEM1467 3 Room size in which approximately 7000 ions per cubic centimeter can be measured in the center of the room when the product is placed next to a wall is running at MED mode settings and is at a height of approximately 1 2 meters from ...

Страница 14: ...12 Memo FP A80M indd 12 FP A80M indd 12 2022 03 01 11 25 08 2022 03 01 11 25 08 ...

Страница 15: ...13 Memo FP A80M indd 13 FP A80M indd 13 2022 03 01 11 25 08 2022 03 01 11 25 08 ...

Страница 16: ...TINS B446KKRZ 22C 1 FP A80M indd 14 FP A80M indd 14 2022 03 01 11 25 08 2022 03 01 11 25 08 ...