FO-4650U
2 – 1
CHAPTER 2. ADJUSTMENTS
[1] Adjustments
General
Since the following adjustments and settings are provided for this model,
make adjustments and/or setup as necessary.
1. Adjustments
Adjustments of output voltage (FACTORY ONLY)
1. Install the power supply unit in the machine.
2. Set the recording paper and document.
3. When the document is loaded, power is supplied to the output lines.
Confirm that outputs are within the limits below.
Output voltage settings
Fig. 1
CNPW
CNPRT
CN1
IC2
CN1
CN7
CN4
1
1
1
1
11
11
8
1
1
1
1
12
30
30
12
8
CONTROL
PWB
PRINTER
PWB
HI VOLTAGE
PWB
CN5
CN1
POWER SUPPLY
PWB
IC2
VR1
VD
Voltage for adjust
+ Check point for voltage
Digital multi meter
+
–
–
Connector
CN5
No.
Pin No.
CNPW
1
+24V SUB
2
MG
3
MG
4
MG
5
+24V MAIN
6
+24V MAIN
7
+5V SUB
8
DG
9
DG
10
DG
11
+5V MAIN
12
+5V MAIN
Connector
CN4
No.
Pin No.
CN1
1
11 +5V
2
10 HV C HL
3
9
T VR
4
8
T REM
5
7
T MON
6
6
B MON
7
5
B VR
8
4
C REM
9
3
C MON
10
2
MG
11
1
+24
Connector
CN1
No.
Pin No.
CN7
1
24 MAIN
2
MG
3
DG
4
5V MAIN
5
HEATER ON
6
FAN
7
FAN LOCK
8
H RELAY OFF
Output
Voltage limits
+5V MAIN
4.845V~5.355V
+5V SUB
4.845V~5.355V
+24V MAIN
23.04V~24.96V
+24V SUB
23.04V~24.96V
Top Void Printer
Adjust Voltage
Label (mm.) Fig. 2
VR1 Fig. 1
5.5~6.9
4.42V
7.0~8.9
3.87V
9.0~10.9
3.14V
11.0~12.9
2.50V
13.0~14.9
1.86V
15.0~17.0
1.22V
ADJUST VOLTAGE LIST
TOP VOID LABEL
Fig. 2
2
(step 1) Select "OPTION SETTING".
DISPLAY:
DISPLAY:
DISPLAY: TONE SELECTED
KEY:
FUNCTION
4
KEY:
4:OPTIONAL SETTING
ENTER #(01-34, ,#)
KEY:
DIAL MODE
1=TONE, 2=PULSE
KEY:
KEY:
DISPLAY:
(step 4) End, using the "STOP" key.
(step 3) Select, using "1" or "2".
(step 2) Select "DIAL MODE".
1
2
PULSE SELECTED
STOP
Cursor
When initially registering,
the mode shows 1=TONE.
When registering again, the
mode which was registered
formerly is shown.
2
2. IC protectors replacement
ICPs (IC Protectors) are installed to protect the TX motor drive circuit
and verification stamp drive circuit. ICPs protect various ICs and elec-
tronic circuits from an overcurrent condition.
The location of ICPs are shown below:
(1) F100 (ICPS10) is installed in order to protect IC’s from and
overcurrent generated in the verification stamp drive circuit. If F100
is open, replace it with a new one.
(2) F101 (ICPS18) is installed in order to protect IC’s from an overcurrent
generated in the TX motor drive circuit. If F101 is open, replace it
with a new one.
In addition to the replacement of F101 and F100, the factor causing
F101 and F100 to open must also be repaired. If not, F101 and
F100 will open again.
Replacement parts
ICPS10 (Sharp code: VHViCPS10//-1)
ICPS18 (Sharp code: VHViCPS18//-1)
3. Settings
(1) Dial mode selector
OPTION SETTING: DIAL MODE (Soft Switch No. SW2 DATA No. 1)
Use this to set the fax machine to the type of telephone line you are on.
• The factory setting is "TONE".
Fig. 3
CONTROL PWB
(BOTTOM SIDE)
F100
F101
IC7
CNSP
CNSEN
CNCIS
CNPN
CNSTP
CNTXM
CNPW
CNPRT
CNLIU
1
1
2
1
8
10
1
1
1
1
1
50
27 25
1
1
30
12
4
2
24
9
CNOP
Содержание FO-4650
Страница 30: ...FO 4650U Control PWB parts layout Top side 6 17 ...
Страница 31: ...FO 4650U Control PWB parts layout Bottom side 6 18 ...
Страница 33: ...FO 4650U LIU PWB parts layout 6 20 ...
Страница 36: ...FO 4650U Printer PWB parts layout Top side 6 23 ...
Страница 37: ...FO 4650U Printer PWB parts layout Bottom side 6 24 ...
Страница 39: ...FO 4650U Power Supply PWB parts layout 6 26 ...