PRO-60/70X5FD
6 – 3
LED flashing timing chart at the time of an error
1) Slow flashing
Note
2) Inverter/Lamp failure details (Flashes slowly once and flashes fast)
Note
3) Power failure details (Flashes slowly twice and flashes fast)
Note
Error type
Power LED operation
Pins are monitor microcomputer pins.
Inverter/Lamp failure
Flashes slowly once
H: On
L: Off
Refer to “Inverter/Lamp failure details”.
Flashes slowly and fast by pressing the [MENU] key on
the remote control (refer to 2 below).
Power failure
Flashes slowly twice
H: On
L: Off
Refer to “Power failure details”.
Flashes slowly and fast by pressing the [MENU] key on
the remote control (refer to 3 below).
Main CPU to main CPU
communication failure
Flashes slowly 3 times
H: On
L: Off
Refer to “Communication failure details”.
Flashes slowly and fast by pressing the [MENU] key on
the remote control (refer to 4 below).
Communication line failure or main CPU communication
failure.
→
Check debug statements for the main CPU.
Others
Flashes slowly 4 times
H: On
L: Off
Refer to “Other failure details”.
Flashes slowly and fast by pressing the [MENU] key on
the remote control (refer to 5 below).
Error type
Power LED operation
Pins are monitor microcomputer pins unless other-
wise specified.
Lamp failure
Flashes fast once
H: On
L: Off
ERR_PNL: Hi failure. Confirmed after 8 consecutive
detections at 64 msec intervals (detected only when the
backlight is on).
Note that after five detection counts, the lamp cannot be
activated except in the monitor process.
Accumulated counts are cleared to 0 by the setting in the
process A.
Error type
Power LED operation
Pins are monitor microcomputer pins unless other-
wise specified.
PS_ON
AC_DET failure
Flashes fast once
H: On
L: Off
AC_DET failure (L).
If error is detected during start-up or operation, the
power is turned on again by interrupt (instantaneous
blackout processing).
SM_POW
Main 13V failure
Flashes fast twice
H: On
L: Off
DET_13V failure (L). Main 13V is not applied.
If error is detected during operation, error standby is
activated by polling.
D_POW
Digital 3.3V error
Flashes fast 3 times
H: On
L: Off
DET_D3V3 failure (L). Digital 3.3V is not applied.
If error is detected during operation, error standby is
activated by polling.
PANEL_POW
Panel 12V failure
Flashes fast 5 times
H: On
L: Off
DET_PNL12V failure (L). Panel power is not applied.
If error is detected during operation, error standby is
activated by polling.
100ms
400ms
1.6sec