PRO-60/70X5FD
6 – 2
Table 1. Concrete flashing pattern (Error standby)
*2: They depend on the system. Power supply error is defined from product to product.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
Table 2. Concrete flashing pattern (Verup, etc.)
*4: If the boot section is abnormal, there is no flashing (flashing impossible).
3. New method
Item
Outline display
Detail display
Cause
Slow flashing
Fast flashing
Slow flashing
Fast flashing
Inverter/Lamp system
failure
Flashes once
None
Flashes once
Flashes once
Lamp error
Power PWB failure
(Power failure, etc.)
Flashes twice
None
Flashes twice
Flashes once
Power supply error 1 (*2) AC_DET error
Flashes twice
Power supply error 2 (*2) UR+13V error
Flashes 3 times
Power supply error 3 (*2) D3.3V error
Flashes 5 times
Panel power supply error
Main PWB failure
(Communication fail-
ure, etc.)
Flashes 3 times
None
Flashes 3 times Flashes once
Initial communication error
Flashes twice
Start-up confirmation communication error
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
Others
Flashes 4 times
None
Flashes 4 times Flashes once
Temperature error
Flashes twice
Sync error
Flashes 3 times
Notification from the main microcomputer (*3)
Item
Display
Note
Ver UP executing
Flashes continuously (1 sec cycle)
The flash only when rewriting the sub microcomputer.
Ver UP succeeded
Flashes continuously (4 sec cycle)
The flash only when rewriting the sub microcomputer.
ROM data failure
Flashes continuously (400 msec cycle, On period: 100 msec)
Start-up after failing version upgrade (*4)
•
Flashing during Verup
•
Flashing when completing Verup
PowerLED
1600ms
300ms
100ms
400ms
400ms
1600ms
Power LED
500ms
500ms
Power LED
2000ms
2000ms