10
11
WHAT YOU NEED TO KNOW\HOW TO OPERATE
CONTROL PANEL
EASY-TO-USE FUNCTIONS
HOW TO OPERATE
After you insert the power plug, all the LED indicators and digital display are on for 1 second and then turn
off. Meanwhile, the buzzer sends three alert sounds. Each time you press a button, the buzzer sends a
alert tone. When you press the ON/OFF button to power the unit off, the buzzer sends a long beep
sound.
After you press the ON/OFF button to power the unit on and the buzzer sends a alert
tone, the dehumidifier starts the continuous dehumidifying mode, the power indicator
and continuous dehumidifying function indicator are turned on, and the dual-digit
display shows the current humidity. Moreover, the unit automatically set the louver to
the position of 85°.
After you press the ON/OFF button to power the unit off during operation of the
dehumidifier, the dehumidifier will stop operation, and the louver will be closed
automatically. Meanwhile, the buzzer sends out a long beep.
Press the MODE button. You can select among the four dehumidifying modes:
LAUNDRY, COMFORT, CONTINUOUS and AUTO.
1. LAUNDRY: The laundry indicator is turned on, the compressor starts, and the fan
runs at the highest speed to dry clothes. The dehumidifier will not stop until the water
tank is full.
[When you want to dry clothes]
2. COMFORT: The Comfort indicator is turned on, the dehumidifier dehumidifies while
the compressor starts or stops so that the relative humidity is kept at comfortably 60%,
and the fan rotates at the low speed.
[When you want the dehumidifier to automatically control the humidity so that the
relative humidity is fixed at the comfortable value.]
3. CONTINUOUS: The Continuous indicator is turned on, the compressor starts, the
fan rotates at the low speed, and the dehumidifier continues dehumidifying until the
water tank is full.
[When you want to always keep dry]
AUTO DEFROST
●
During defrosting, the defrosting indicator is on, the compressor stops, and the fan keeps rotating at the
highest speed. After the defrosting ends, the dehumidifying function starts, the compressor restarts, and the
fan resumes the preset speed.
When the temperature sensor fixed on the copper pipe of evaporator detects that the dehumidifier temperature
is lower than or equal to -1°C (and the relative room temperature is lower than or equal to 13°C), the
dehumidifier will start the automatic defrosting procedure, namely, the dehumidifier defrosts automatically after
the dehumidifying mode runs for 20 minutes; when the evaporator surface is defrosted completely, the
temperature sensor detects that the temperature is higher than or equal to 2°C and the defrosting duration is
longer than or equal to 10 minutes, the dehumidifier will stop defrosting and enable the dehumidifying function.
●
COMPRESSOR STOP/START PROTECTION
●
During operation, if the compressor stops due to any operation, the dehumidifier will automatically switch to
the function of restarting the compressor after stopping it for 3 minutes, namely, the compressor cannot be
restarted in 3 minutes, but other functions are available.
In the dehumidifying mode, if you remove and replace the water tank or power off and power back on the
dehumidifier, the dehumidifying function will start after an interval of 3 minutes.
●
8IFOUIFEFIVNJEJGJFSPQFSBUFTBUBMPXUFNQFSBUVSFUIFFWBQPSBUPSTVSGBDFNBZCFGSPTUFE5P
FOTVSFOPSNBMPQFSBUJPOUIFEFIVNJEJGJFSQSPWJEFTUIFBVUPNBUJDEFGSPTUJOHGVODUJPO