![Sharp CP-E9000H Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/sharp/cp-e9000h/cp-e9000h_service-manual_372560070.webp)
MD-E9000H
– 70 –
The tracking servo is not activated.
Check the peripheral circuits at pins 9 and 10 on IC1, and circuit
around CNP2.
If the waveform shown in Figure 70-1 appears and soon after
NO DISC appears ?
(2) Tracking system check.
Check the TE waveform at pin 15 on IC1.
A normal jump operation cannot be completed or the beginning of
the track cannot be found.
Check the around pin 20 on IC1.
"Initialization" is possible, but play is not possible ?
Data cannot be read. Check the VCO-PLL system.
"Initialization" is not possible.
Figure 70-1
Figure 70-2
Press the OPEN/CLOSE switch without inserting a disc, and
then try starting the play operation.
(3) Spin system check.
The spin driver circuit is OK.
1. The turntable rotates a little ?
(Waveform drawing Figure 70-2.)
Check around pin 22 on IC1, pins 20 and 21 on IC2, and around
CNP4.
2. The turntable doesn't rotate.
No
Yes
No
Yes
Yes
No
T
T
TE
DRF
Stopped
CH1=10 V
DC 10:1
CH2=1 V
DC 10:1
100 ms/div
(100 ms/div)
NORM: 100 kS/s
2
1
=Record Length=
Smoothing : ON
CH1 : 0.0 V
CH2 : 0.00 V
Main : 100 K
Zoom : 2 K
Mode : NORMAL
Type : EDGE CH1
Delay : 2.924 ms
Hold off : 0.2
µ
s
CH3 : 0.00 V
CH4 : 0.00 V
BW : FULL
=Trigger=
=Filter=
=Offset=
T
T
FDO
SPDO
Stopped
CH1=200 mV
DC 10:1
CH2=500 mV
DC 10:1
500 ms/div
1999/04/07 09:51:15
(500 ms/div)
NORM: 20 kS/s
2
1
=Record Length=
Smoothing : ON
CH1 : 0.000 V
CH2 : 0.000 V
Main : 100 K
Zoom : 2 K
Mode : NORMAL
Type : EDGE CH2
Delay : 2.924 ms
Hold off : 0.2
µ
s
CH3 : 0.00 V
CH4 : 0.00 V
BW : FULL
=Trigger=
=Filter=