CD-K477W
– 18 –
SW1
OPEN/CLOSE
ON—OFF
SW2
MECHA UP
ON—OFF
SW3
DISC NUMBER
ON—OFF
SW4
PICKUP IN
ON—OFF
SW991
VOLTAGE SELECTOR
230-240V
SWD1
VOLUME JOG
ON—OFF
SWD2
JOG
ON—OFF
SWD3
X-BASS
ON—OFF
SWD4
PRE EQ
ON—OFF
SWD5
MENU
ON—OFF
SWD12
TUNING UP/CUE
ON—OFF
SWD13
STOP
ON—OFF
SWD14
NORMAL EDIT
ON—OFF
SWD15
HIGH EDIT
ON—OFF
SWD16
REC/PAUSE
ON—OFF
SWD17
F-PLAY
ON—OFF
SWD19
SUB WOOFER VOLUME UP
ON—OFF
SWD20
SUB WOOFER VOLUME DOWN
ON—OFF
SWD24
4SP-1
ON—OFF
SWD25
4SP-2
ON—OFF
SWD27
PHANTOM
ON—OFF
SWD28
NORMAL
ON—OFF
SWD29
BYPASS
ON—OFF
SWD30
TUNING DOWN/REWIND
ON—OFF
SWD31
CD PAUSE
ON—OFF
SWD32
REVERSE MODE
ON—OFF
SWD33
R-PLAY
ON—OFF
SWD34
CLOCK
ON—OFF
SWD35
MEMORY
ON—OFF
SWD36
TIMER
ON—OFF
SWD37
SLEEP
ON—OFF
SWD38
CLEAR
ON—OFF
SWD39
VIDEO/AUX 1
ON—OFF
SWD40
VIDEO/AUX 2
ON—OFF
SWD41
TAPE 1/2
ON—OFF
SWD42
TUNER/BAND
ON—OFF
SWD43
CD
ON—OFF
SWD48
POWER
ON—OFF
SWD49
KARAOKE
ON—OFF
SWD50
DISC 1
ON—OFF
SWD51
DISC 2
ON—OFF
SWD52
DISC 3
ON—OFF
SWD53
DISC SKIP
ON—OFF
SWD54
OPEN/CLOS
ON—OFF
SWF2
SPAN SELECTOR
50/9
SWM3
REC FWD
ON—OFF
SWM4
REC RVS
ON—OFF
SWM5
F.A.S
ON—OFF
SWM6
CAM
ON—OFF
•
The indicated voltage in each section is the one measured
by Digital Multimeter between such a section and the chas-
sis with no signal given.
1. In the tuner section,
( ) indicates AM
< > indicates FM stereo
2. In the main section, a tape is being played back.
3. In the deck section, a tape is being played back.
( ) indicates the record state.
4. In the power section, a tape is being played back.
5. In the CD section, the CD is stopped.
•
Parts marked with “ ” ( ) are important for
maintaining the safety of the set. Be sure to replace these
parts with specified ones for maintaining the safety and
performance of the set.
NOTES ON SCHEMATIC DIAGRAM
•
Resistor:
To differentiate the units of resistors, such symbol as K and
M are used: the symbol K means 1000 ohm and the symbol
M means 1000 kohm and the resistor without any symbol is
ohm-type resistor. Besides, the one with “Fusible” is a fuse
type.
•
Capacitor:
To indicate the unit of capacitor, a symbol P is used: this
symbol P means micro-micro-farad and the unit of the
capacitor without such a symbol is microfarad. As to
electrolytic capacitor, the expression “capacitance/withstand
voltage” is used.
(CH), (TH), (RH), (UJ): Temperature compensation
(ML): Mylar type
(P.P.): Polypropylene type
•
Schematic diagram and Wiring Side of P.W.Board for this
model are subject to change for improvement without prior
notice.
REF. NO
DESCRIPTION
POSITION
POSITION
REF. NO
DESCRIPTION
Figure 18 TYPES OF TRANSISTOR AND LED
KTA1266 GR
KTA1270Y
KTA1271 Y
KTC3199 GR
KTC3203 Y
KRA102 M
KRA109 M
KRC102 M
KRC104 M
KRC107 M
2SC535 C
2SD468 C
2SC2878 A
2SD2012
2SB1375
SLR325 MG
SLR325 VR
KL052 UL
SLR505 MC
LMKD515B
KV1236Z23
(S) (G) (D)
(1) (2) (3)
E C B
FRONT
VIEW
FRONT
VIEW
B C E
(D) (G) (S)
(3) (2) (1)
FRONT
VIEW
FRONT VIEW