7 – 2
5. Remove the two (2) screws holding the back plate to the rear
angle.
6. Remove the four (4) screws fixing the back plate.
7. Now, the back plate with exhaust cover is free.
[4] DOOR ASSEMBLY REPLACEMENT
1. REMOVAL
1. Disconnect the power supply cord.
2. Wait for 60 seconds to discharge the high voltage capacitors of the
inverter unit.
3. Remove the outer case cabinet, referring to “OUTER CASE
REMOVAL”.
4. Remove the dew tray
5. Disconnect the 12-pin connector of the control panel harness.
6. With the door open 45
°
, push the door cam down and back and
then slowly open the door to remove it.
7. With the door open more than 106
°
, slide the door left from the
hinge pin slot to remove it.
NOTE: Be careful not to make the 12-pin harness caught in the
square hole of the oven.
Be careful when installing the door, since the door cam is eas-
ily pulled in the back of the oven.
After replacing the door or loosening/removing the hinge
screws, make sure to adjust the door.
2. REINSTALL
1. To facilitate reinstallation, first put the hinge pin in the right hinge.
CAUTION: If bent, the comb-shaped teeth should be straighten (other-
wise, microwave leakage may result.)
After replacing or repairing the door, ensure that there is no
microwave leakage (otherwise, microwave leakage may
result).
Always make latch adjustment (otherwise, malfunction may
result)
3. After any service to the door
1) Make sure that the door sensing switch, the secondary interlock
switch and the monitor switch are operating properly. (Refer to
chapter “Test Procedure”.)
2) An approved microwave survey meter should be used to assure
compliance with proper microwave radiation emission limitation
standards.
[5] DOOR COVER REMOVAL AND DOOR PACKING INSTALLATION
1. DOOR COVER REMOVAL
1. Disconnect the power supply cord.
2. Wait for 60 seconds to discharge the high voltage capacitors of the
inverter unit.
3. Put a putty knife (thickness of about 0.5mm) into the gap between
the door cover and the door frame (for tab positions, refer to photo).
First disengage four(4) tags on the right side, four(4) tags on the left
side, and six(6) tags on the front side.
4. Lift up the this side of the door cover. And disengage the center tab
and the seven (7) tabs on the back side. If it is difficult to disengage
the seven (7) tabs on the back side, remove the door packing.
5. Remove the door packing from the door cover.
6. Following the above steps 3, 4 and 5 can remove the door cover
without breaking it.
NOTE: * Embed the entire circumference of the door packing in the
door cover and then fit the door packing with the door
frame.
* After assembling, press the entire circumference of the
door packing so that the door packing is in a uniform condi-
tion without protrusion.
* Be careful not to damage the surface.
* After assembling, check that there is no microwave/steam
leakage from the door.
2. DOOR PACKING INSTALLATION
1. Turn the door cover over.
2. Install the four (4) corners of the door packing into the four (4) cor-
ners of the door cover opening.
3. As the cross section of the door cover opening is T character type,
put the door packing over the door cover opening.
Panel R
Handle
Slide to left
Door Cam
Door Cam
106º
Door Cover
Door packing
This side
Positions of tabs
Right side
Left side
Door cover
Center tab
Magnified picture of the door packing
Groove of
the door packing
Door packing
Reverse side of the door cover
T character part of the door cover
Magnified picture of the door cover
Содержание AX-GX2T(R)
Страница 8: ...4 2 2 OVEN COMPONENTS ILLUSTRATION 1 OVEN ...
Страница 9: ...4 3 ...
Страница 10: ...4 4 2 CONTROL PANEL ...
Страница 11: ...4 5 ...
Страница 13: ...4 7 How to carry out citrate washing Carry out citrate washing if the display unit is replaced ...