AR-RB1 UNPACKING AND INSTALLATION 2 - 2
Parts included
1. Turn off the main switch of the main unit.
1) Turn the main switch located on the left side of the main unit to the
"OFF" position.
2) Then remove the power plug of the main unit from the outlet.
2. Remove the actuator.
1) If the exit tray is installed to the main unit, remove it.
2) While holding the base of the exit actuator of the main unit with one
hand, pull the end of the actuator with the other hand to remove
the actuator.
3. Remove the paper output section covers.
1) Pull the centers of the two paper output section covers on the left
side of the main unit to remove them.
In the case of AR-D17/D18:
1) Pull the lock release lever on the left side of the main unit to pull
out the left cover until it stops.
2) Pull the upper part of the paper input section cover on the left side
of the optional stand to remove the paper input section cover.
Transport guide holder: 2 pcs.
Actuator: 1 pc.
Transport guide: 1 pc.
"OFF"
Exit actuator
Paper output
section covers
Lock release lever
Left cover
Paper input section cover