AR-M205 SIMULATIONS 7-6
09
01
Duplex motor forward rotation
check
The duplex motor is driven in forward direction (in the paper exit direction) for 30 sec.
During the process, the display section displays the sub code.
After completion of the process, the machine goes into the sub code input standby mode.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
02
Duplex motor reverse rotation
check
The duplex motor is driven in reverse direction for 30 sec.
During the process, the display section displays the sub code.
After completion of the process, the machine goes into the sub code input standby mode.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
04
Duplex motor RPM adjustment
When any key input is made, it is displayed on the display section.
When the [START] key is pressed, the set code data are acquired and stored in the EEPROM, and
the machine goes into the sub code input standby mode.
When, however, the [START] key is pressed outside the set range, it is not assured.
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
05
Duplex motor switchback time
adjustment
When any key input is made, it is displayed on the display section. When the [START] key is pressed,
the set code data are acquired and stored in the EEPROM, and the machine goes into the sub code
input standby mode.
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
10
-
Toner motor operation
When the [START] key is pressed, the toner motor is driven for 30 sec.
After completion of the process, the machine goes into the main code input standby mode.
When the [Interrupt] key is pressed, the machine goes into the main code input standby mode.
14
-
Trouble cancel (except for U2)
*
Trouble to write into the EEPROM such as H trouble is canceled and hardware reset is
performed.
16
-
U2 trouble cancel
*
U2 trouble is canceled and hardware reset is performed.
20
01
Maintenance counter clear
When the [Start] key is pressed, the maintenance count value is cleared and "000000" is displayed.
(Alternate display of "000" and "000")
21
01
Maintenance cycle setting
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
02
Mini maintenance cycle setting
(Valid only when the destination is
set to Japan AB series.)
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
22
01
Maintenance counter display
The maintenance counter value is displayed.
02
Maintenance preset display (Valid
only when the destination is set to
EX Japan)
The copy quantity corresponding to the code that is set with SIM21-01 is displayed.
(For example: 50,000 sheets)
03
Jam memory display
The LED of the latest jam position is lighted. Every time when the magnification ratio display key is
pressed, the jam memory data is acquired sequentially from the latest. The jam position is judged by
the acquired data and the corresponding LED is lighted. The 7-seg display indicates the jam number.
At that time, "A" is displayed on the upper first digit. When the last one is displayed, the latest one will
be displayed again. Max. 30 jams from the latest are stored. When the [Interrupt] key is pressed, the
machine goes into the sub code input standby mode. When the [CA] key is pressed, the simulation is
terminated.
04
Jam total counter display
The jam total counter value is displayed.
05
Total counter display
The total counter value is displayed.
06
Developing counter display
The developing counter data is acquired and displayed on the 7-seg display.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
Main
code
Sub
code
Contents
Details of operation
Set range: 1 - 13
Default: 4
(Change quantity 1
1-2 phase 3 steps)
Set range: 50 ~ 76
Default: 50
Code
Setting
0
1
2
3
4
5
5,000 sheets
7,500 sheets
10,000 sheets
25,000 sheets
50,000 sheets * Default
Free (999,999 sheets)
Code
Setting
0
1
2
5,000 sheets * Default
10,000 sheets
Free (999,999 sheets)