SPECIFICATIONS
1 - 6
K. Charger wire cleaning
Note 1: The charging wire is cleaned.
L. Special functions
Charger wire cleaning
Available (Auto cleaning system)
Interruption
Available
Available
Key input is accepted
during warming up and in
the ready state.
Note 1: Auto pre-heat function can be set in the adjustment
mode.
Note 2: By data input of the adjustment mode, time can be
set in the increment of 5min (5 – 60min).
Factory setup (Note 2)
North America, Europe:
15min
Others: Cancel
Pre-heat
Note 3: The fuser temperature in pre-heat can be set in the
adjustment mode.
Factory setup (Note 3); 170
C
Available
Auto clear
Setup can be changed in the adjustment mode.
(15 – 150sec, in the increment of 15sec, and cancel of
setup)
Factory setup: 45sec
Available
Note 1: Time up to OFF can be changed in the adjustment
mode or in the adjustment screen setup. (Max. 240min.
Only the adjustment code can be canceled.)
Note 2: Use or non-use can be selected in the adjustment
mode.
Factory setup (Note 1, 2)
North America, Europe:
90min
Others: Not used.
Auto off
Note 3: For time setup, selection of User adjustment
Allow/Not Allow can be made.
Factory setup (Note 3)
North America, Europe:
Available
Others: Not Available
Self diag
Available
Error code history
Available
Password code
Available
Factory setup: OFF
Dew-prevention
Available (Optional in some destinations)
Message
Available
Note 1: Graphic LCD, backlight provided.
All clear
Available
AC key
Mode memory
Available (4 modes)
Cover paper mode
Available (in the following 4 modes)
(1) White cover mode
(2) Copy cover mode
(3) White cover/white back cover mode
(4) Copy cover/white back cover mode
Sheet insertion mode
Available (in the following 2 modes)
(1) White paper insertion mode
(2) Copy paper insertion mode
Weekly timer
Available
Pre-heat start
Available
Pre-heat copy
Available
Auto duplex auto
selection
Available
Factory setup: OFF