[10] MAINTENANCE
1. Maintenance table
✕
: Check (Clean, adjust, or replace when required.) : Clean
▲
: Replace : Adjust
✩
: Lubricate
Unit name
Part name
When calling or
replacing the kit
150k
Transfer section
Charger unit
Transfer paper guide
Optical section
Lamp unit
Reflector
Mirror
No. 2/3 mirror unit
Mirror
Pulley
✕
✕
CCD peripheral
Lens
Glass
Table glass
White plate
Other
Drive wire
✕
✕
Rail
✕✩
✕✩
Document cover
Document size sensor
LSU
Dust-proof glass
Paper feed section
Multi paper feed section
Takeup roller
Paper feed roller
Spring clutch
✩
✩
Cassette section
Paper feed roller
Spring clutch
✩
✩
Paper transport section
PS roller
Transport (paper exit) rollers
Spring clutch
✩
✩
Fusing section
Upper heat roller
▲
Pressure roller
Pressure roller bearing
✕
✩
Upper separation pawl
✕
Lower separation pawl
✕
Drive section
Gears
✕✩
✕✩
Belts
✕
Paper exit section
Ozone filter
✕
✕
∗
1: Recommendable replacement time: 30K (A4 (8.5"
×
11"), 6% print)
2. Maintenance display system
Toner
Life
13K
Remaining
quantity check
∗
1
a. Press and hold the density adjustment LIGHT key for more than 5 sec, and the machine will enter the
user program mode.
b. Press and hold the "%" key for more than 5 sec, and the remaining quantity will be displayed on the copy
quantity display in one of the following levels: (Remaining quantity display levels: 100%, 75%, 50%, 25%,
10%, LO)
c. Press the density adjustment LIGHT key to cancel.
Remaining
quantity
NEAR EMPTY
About 10%
EMPTY
LED
ON
Flash
Machine
Operation allowed
Stop
Developer
Life
30K
LED
ON at 30K of the developer count.
Machine
Selection is available between Not Stop and Stop by Service Simulation (SIM 26-37) Setup.
(If Stop is selected, the LED will flash and stop at 30K.)
∗
Default: Not Stop
∗
Clear: SIM 42-1
Maintenance
LED
Selection is available among 30K, 15K, 10K, 7.5K, 5K, and free (no lighting) with SIM 21-1.
∗
Default: 30K
∗
Clear: SIM 20-1
Machine
Not stop.
∗
1: Installation of a new toner cartridge allows to display the remaining quantity.
∗
1
AR-162 [10] MAINTENANCE 11/21/2000
AR-162 MAINTENANCE – 1