Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
26
10
Model name setting
Used to set the model name of the machine used with the following
numbers. After entering the set value, press the start key and the set
value is stored.
0
0
∼
19
22
Language setting
Used to display the current setting of the language information with the
number at right. After entering the set value, press the start key, and the
set value is stored.
0
0
∼
7
30
CE mark conformity
control setting
Used to display the current setting of CE mark conformity control with
the number at right. After entering the set value, press the start key, and
the set value is stored.
0
0
∼
1
32
Fan rotation duty change
state setup
The currently set fan motor rotation duty is displayed with the following
numbers. After entering the set value, press the start key to store the
set value.
0
0.1
38
Cancel of stop at drum
life over
<Not Used>
The currently set value is displayed. After entering the set value, press
the start key to store the set value.
0
0
∼
1
42
Transfer timing adjustment
After completion of warm up, shading is performed and the currently set
transfer timing adjustment value is displayed.
5
1, 3, 5, 7, 9
50
Black-white reversion
function setup
The current setup of black-white reversion is displayed with the following
numbers. After entering the set value, press the start key to store the
set value.
0
0.1
Key operation/Display
0: AL-1600
11: AR-N200
1: AL-1610
12: AR-N205
2: AL-1620
13: AL-1621
3: AL-1640/AL-1641
14: AL-1650
4: AR-160/AR-S160
15: AL-1670
5: AR-161/AR-S161
16: AR-F200
6: AR-200S
17: DM-2000
7: AR-200/AR-S200
18: DM-2005
8: AR-205/AR-S205
19: DM-2010
9: AR-F160
10: AR-F205
Key operation/Display
0: Japanese
4: Italian
1: English
5: Dutch
2: French
6: Swedish
3: German
7: Spanish
Key operation/Display
0: CE mark control OFF
1: CE mark control ON
Key operation/Display
0: Operating 50%, standby 30%
1: Operating 80%, standby 50%
Key operation/Display
0: The machine stops at drum life over.
1: The machine does not stop at drum life over.
Key operation
Transfer timing adjustment value: Copy quantity keys
“1”: 240 ms
“3”: 260 ms
“5”: 280 ms
“7”: 300 ms
“9”: 320 ms
Key operation/Display
0: Black-white reversion function enabled
1: Black-white reversion function disabled
AR-205
7 – 8
Содержание AR-160
Страница 72: ... 13 ELECTRICAL SECTION 1 BLOCK DIAGRAM AR 205 13 1 ...
Страница 73: ...2 ACTUAL WIRING DIAGRAM ACTUAL WIRING DIAGRAM 1 3 13 2 13 3 AR 205 AR 205 ...
Страница 74: ...ACTUAL WIRING DIAGRAM 2 3 13 4 13 5 AR 205 AR 205 ...
Страница 75: ...ACTUAL WIRING DIAGRAM 3 3 13 6 13 7 AR 205 AR 205 ...