LC-80LE632U
5 – 14
2
Automatic
adjustment exe-
cution
[Command]
Process mode
KRSW0001
KKT10037
Setting
KY0F0000
0SDS0001
SBSL0016
Multi-point adjustment mode
MREN0000
MSET0011
Point 6
LEV60232
MG6G****
MG6B****
MG6R****
Point 5
LEV50201
MG5G****
MG5B****
MG5R****
Point 4
LEV40150
MG4G****
MG4B****
MG4R****
Point 3
LEV30112
MG3G****
MG3B****
MG3R****
Point 2
LEV20074
MG2G****
MG2B****
MG2R****
Point 1
LEV10041
MG1G****
MG1B****
MG1R****
Writing
MSET0003
[Adjustment procedure]
1) Send the “adjustment process” code using the remote control.
2) Set the point 6 to the specified gradation, specify the strongest color as the fixed
color, and adjust the RGB so that it becomes the standard value through negative
adjustment.
3) Set the point 5 to the specified gradation, set the G correction value (804 x G value of
point 6/928) (fractions rounded off), and adjust the RB so that it becomes the stan-
dard value.
4) Set the point 4 to the specified gradation, set the G correction value (600 x G value of
point 6/928) (fractions rounded off), and adjust the RB so that it becomes the stan-
dard value.
5) Set the point 3 to the specified gradation, set the G correction value (448 x G value of
point 6/928) (fractions rounded off), and adjust the RB so that it becomes the stan-
dard value.
6) Set the point 2 to the specified gradation, set the G correction value (296 x G value of
point 6/928) (fractions rounded off), and adjust the RB so that it becomes the stan-
dard value.
7) Set the point 1 to the specified gradation, set the G correction value (1164 x G value
of point 6/928) (fractions rounded off), and adjust the RB so that it becomes the stan-
dard value.
8) Write the adjustment value by the MSET0003 command and turn off the AC power.
* RGB initial value of point 6: Set gradation 928
* RGB initial value of points 1 to 5: G correction value of each point
(At each point, make adjustment so that the remainder of the RGB adjustment value/
4 is equal.)
[Adjustment value]
* According to the “Standard settings” submitted by the Technical Department
[LC80LE632UN] teaching set
Teaching must be made with the unevenness cancellation off.
(Unevenness cancellation OFF command: MREN0000)
Adjustment
point
Adjustment conditions
Adjustment procedure