LC-60LE635E(B),RU(B)/636E(B),S(B)/638E(B)
5 – 10
3) Volume maximum level [MAXIMUM VOLUME]
4) Volume fixed [VOLUME FIXED]
5) Volume fixed level [VOLUME FIXED LEVEL]
6) Remote control operation [RC BUTTON]
7) Main Unit Operation [PANEL BUTTON]
Remarks
In selecting “QUICK”, the function does not work for the following items. (selection impossible.)
• ON TIMER, QUICK START, DIGITAL FIXED, etc.
* These items does not exist according to the model.
Option
0~60 (loop disabled)
Default
60
Function
The volume cannot be increased more than the adjusted value (the main unit’s speaker only).
Remarks
• When setting to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
• The volume of the headphones is limited.
• The setting is impossible when VOLUME FIXED is set to FIXED.
Option
“VARIABLE”, “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default
“VARIABLE”
Function
• VARIABLE
• FIXED
• AC CTRL
• AC/RC CTRL
: The volume is not fixed.
: The volume is fixed to the value adjusted in the volume fixed level.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in the
case of the AC-ON only.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in
any case.
(AC
?
ON, remote control
?
ON, main utit's key
?
ON)
Exception
• In the adjustment process, the volume can be set to any level regardless of this setting.
Disabled key when
setting to FIXED
• VOLUME UP/DOWN [both remote control and main unit]
• MUTE
* Main units's key is enabled for operating menu.
Remarks
• [MAXIMUM VOLUME] has priority to [VOLUME FIXED]
* When setting to FIXED, Maximum volume is fixed.
• The volume of the headphones is fixed.
• When setting to “FIXED”, the volume is not displayed in operating Disabled key.
• In menu operation, the main unit’s keys (Vol (+/-)) are enabled.
• Volume level graphic be omitted to volume level number.
• In setting to FIXED, ONVOL of On TIMER is not selected (Eliminate Item)
• In setting to AC/RC CTRL, ONVOL of On TIMER i is not selected (Eliminate Item)
Option
0~60 (loop disabled)
Default
20
Function
The volume is fixed to the adjusted value (the main unit’s speaker only).
Exception
• In the adjustment process, the volume can be set to any level regardless of this setting.
Remarks
• When [VOLUME FIXED] is set to “VARIABLE”, the setting cannot be changed.
• VOLUME can be abbreviated to VOL.
Option
“RESPOND”, “NORESPOND” or “LIMITED” (loop enabled)
Default
“RESPOND”
Function
The operation of the remote control’s keys is set.
RESPOND
NO RESPOND
LIMITED
: The remote control’s keys in the normal state are enabled.
: The remote control’s keys in the normal state are disabled.
The POWER key (RECEPTION/STANDBY key) is also disabled.
: Only a part of keys (CHANNEL, etc.) is enabled and other keys are disabled.
Exception
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or
Public Mode setting screen.
Remarks
The enable keys when setting to “LIMITED” are depended on Model.
Option
“RESPOND” or “NO RESPOND” (loop enabled)
Default
“RESPOND”
Function
• RESPOND
• NO RESPOND
: The main unit’s keys are enabled.
: The main unit’s keys are disabled excluding the POWER key (RECEPTION/STANDBY key).