24
LC-37D40U
LC-45D40U
Adjustment item
Adjustment conditions
Adjustment procedure
1
HDMI EDID
1
writing
1. With a checker, write HDMI EDID to IC1501, IC1502 (EEPROM)
mounted on the MAIN PWB.
TL1508, 1510: I2C CLK, TL1509, 1511: I2C DATA
TL1512, 1513: Power5V, TL1518, 1519: GND
TL1534, 1535: Write protection (Low)
2. Write date before the HDMI inspection is performed by the checker.
(Otherwise, HDMI will not function.)
2-5. Adjustment of white balance
(1) White balance adjustment
Adjustment item
Adjustment conditions
Adjustment procedure
1
Adjustment
Light level: MAX (+12)
(Place a luminance
meter on the center
of the screen.)
2
Auto adjustment
performance
1. Apply the following settings to the set.
AV MODE: [STANDARD]
Aging Time: 60 Min.
2. Connect a white balance adjustment jig and the set.
3. Use an RS-232C command to display the screen for two-point adjustment.
[Adjustment]
Set the specified gradation for point 6, and adjust RGB to the standard values
of point 6.
Set the specified gradation for point 1. Set G of point 1 to the default value
[(adjusted G value of point 6) / 944, with fractions rounded] and adjust RB
to the standard values of point 1.
Set the specified gradation for point 2. Set G of point 2 to the default value
[(adjusted G value of point 6) / 944, with fractions rounded] and adjust RB
to the standard values of point 2.
Set the specified gradation for point 3. Set G of point 3 to the default value
[(adjusted G value of point 6) / 944, with fractions rounded] and adjust RB
to the standard values of point 3.
Set the specified gradation for point 4. Set G of point 4 to the default value
[(adjusted G value of point 6) / 944, with fractions rounded] and adjust RB
to the standard values of point 4.
Set the specified gradation for point 5. Set G of point 5 to the default value
[(adjusted G value of point 6) / 944, with fractions rounded] and adjust RB
to the standard values of point 5.
[Adjustment values]
Optical measuring machine: [Minolta CA-210] (Focus on the center of the
screen.)
Point 1 standard values: x = 0.295, y = 0.305 (200 gradations)
Point 2 standard values: x = 0.295, y = 0.305 (264 gradations)
Point 3 standard values: x = 0.295, y = 0.305 (464 gradations)
Point 4 standard values: x = 0.295, y = 0.305 (576 gradations)
Point 5 standard values: x = 0.295, y = 0.305 (800 gradations)
Point 6 standard values: x = 0.295, y = 0.305 (944 gradations)
Specified value for adjustment:
±
0.0020, specified value for inspection:
±
0.0035 (point 1)
Specified value for adjustment:
±
0.0012, specified value for inspection:
±
0.0020 (other than the above)
Condition when inspecting the unit
Light level: MAX (+12)
2-6. Key writing
(1) EDID writing (MAIN PWB: HDMI input terminal)
Содержание Aquos LC 45D40U
Страница 45: ...45 LC 37D40U LC 45D40U M E M O ...
Страница 53: ...6 5 4 3 2 1 A B C D E F G H 60 LC 37D40U LC 45D40U IF Unit Side A ...
Страница 56: ...6 5 4 3 2 1 A B C D E F G H 63 LC 37D40U LC 45D40U AC INLET Unit LC 45D40U Only KEY Unit ...
Страница 72: ...79 LC 37D40U LC 45D40U M E M O ...
Страница 80: ...87 LC 37D40U LC 45D40U ...
Страница 109: ...6 5 4 3 2 1 A B C D E F G H 142 LC 37D40U LC 45D40U LED Unit ...
Страница 110: ...6 5 4 3 2 1 A B C D E F G H 143 LC 37D40U LC 45D40U KEY Unit ...