30
LC-26D4U
LC-32D4U
LC-37D4U
PC
Set
Activate process command (STEP 1).
KRSW0001
Command is accepted.
ERR
Activate process command (STEP 2).
KKT10037
Process command is activated.
OK
Set two-point adjustment.
MSET0000
Two-point adjustment is set.
OK
Initialize adjustment values.
MSET0004
Initialization is done.
OK
* Low-side adjustment start
→
* High-side adjustment start
→
Set low-side adjustment point.
SDML0057
Low-side adjustment point is set.
OK
Adjust R and B.
MGLRx x x x , MGLBx x x x
Adjustment values are set.
OK
Completion of low-side adjustment
Set high-side adjustment point.
SDMH0204
High-side adjustment point is set.
OK
Adjust R, G, and B.
MGHRx x x x , MGHGx x x x , MGHBx x x x
Adjustment values are set.
OK
Save adjustment values.
MSET0003
Storing adjustment values
Adjustment values are saved.
OK
Completion of adjustment
Turn off AC power
Repeat until values are
properly adjusted.
Repeat until values are
properly adjusted.
Initialization of adjustment values for
adjustment pattern display
Initialization of adjustment values for
adjustment pattern display
Setting adjustment values
Reflecting specified values
Setting adjustment values
Reflecting specified values
Completion of high-side adjustment
(4) White balance adjustment sequence
Adjustment is available in any input or position. There is no specific order to adjust high and low, either.
Содержание Aquos LC 26D4U
Страница 34: ...34 LC 26D4U LC 32D4U LC 37D4U 6 List of adjustment process modes Display Examples ...
Страница 35: ...35 LC 26D4U LC 32D4U LC 37D4U ...
Страница 55: ...55 LC 26D4U LC 32D4U LC 37D4U M E M O ...
Страница 107: ...128 LC 26D4U LC 32D4U LC 37D4U PACKING OF THE SET X3 X4 X5 X6 S1 S5 S3 S5 S4 S6 S5 S5 Not Replacement item S2 X1 X2 ...
Страница 108: ...129 LC 26D4U LC 32D4U LC 37D4U ...