AL-2051 SIMULATION, TROUBLE CODES 10 - 12
26
20
Rear edge void setup
[Function]
When this simulation is executed, the current set rear edge void is displayed. Enter the code
number corresponding to the desired rear edge void and press [ENTER]/[START] key to save
the setting.
[Operation]
The operation is similar to simulation 26-02.
30
CE mark support control
ON/OFF
[Function]
When this simulation is executed, the current set CE mark support control is displayed. Enter
the code number corresponding to the desired CE mark support control and press [ENTER]/
[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
38
Cancel of stop at drum life
over
[Function]
When this simulation is executed, the current setup of the code number is displayed. Enter the
code number and press the PRINT switch to enable the setup.
[Operation]
The operation is similar to simulation 26-02.
39
Memory capacity check
[Function]
When the simulation is executed, the currently installed SDRAM of the main unit is displayed.
[Operation]
40
Polygon motor OFF time
setup (Time required for
turning OFF after completion
of printing)
[Function]
When this simulation is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
Main
code
Sub
code
Contents
Details of function/operation
Code number
Setting
Display item
Remark
0
Rear edge void NO
OFF
1
Rear edge void YES
ON
Default
Code number
Setting
Display item
Remark
0
CE mark support control OFF
OFF
Default (100V series)
1
CE mark support control ON
ON
Code number
Setup
0
Stop at drum life over * Default (Overseas)
1
Cancel of stop at drum life over
Code number
Setting
Remark
32
32 MBYTE
1) Memory capacity display
26-39 M
E
M
.C
HK
32 MB
YTE
Code number
Setting
Display item
Remark
0
0sec
0 SEC.
1
30sec
30 SEC.
Default
2
60sec
60 SEC.
3
90sec
90 SEC.