E-16
Installing the mounting plate
(1) Referring to the “
INSTALLATION DIMEN-
SION OF INDOOR UNIT
”, mark the location
for the fixing holes and the piping hole.
• Recommended fixing holes are marked in
circle around the hole. (7 points)
• Make sure that the mounting plate is hori-
zontally.
(2) Secure the mounting plate to the wall with
the long screws and check the stiffness.
Wall
Making a piping hole
(1) Drill a piping hole with 70mm diameter concrete
drill or a hole saw with a 5mm down ward
slant to the outside.
(2) Set the sleeve and caps.
1
MOUNTING PLATE
LONG SCREW
Indoor
Outdoor
Cut with a saw.
Cap
5 mm
Sleeve
(Downward to outdoor)
PLACING THE MOUNTING PLATE AND MAKING A PIPING HOLE
LONG SCREW
1
MOUNTING PLATE
SETTING UP THE INDOOR UNIT
1
2
3
4
5
Mounting the indoor unit
For right side piping
(1) Pass the pipes and the drain hose through the piping hole.
(2) Hook the unit onto the mounting plate.
(3) Pull the connecting cable into the indoor unit.
(4) Push the unit and apply the bottom hooks to the
mounting plate's support.
(5) Pull the bottom of the unit to check that the unit is
fixed in place.
For left side piping
(1) Reverse the positions of the drain hose and drain cap.
Refer to “
Exchange the drain hose
”
(2) Connect the pipes and wrap tape around the insula-
tion of the piping joints tightly not to become thick.
(3) Bind the pipes and connecting cable with tape.
(4) Set the pipes and connecting cable along the back
of the unit, and attach the piping holder.
(5) Pass the pipes, connecting cable and the drain
hose through the piping hole.
(6) Hook the unit onto the mounting plate.
(7) Push the unit and apply the bottom hooks to the
mounting plate's support.
(8) Pull the bottom of the unit to check that the unit is
fixed in place.
NOTES:
• Bend the pipes carefully as not to damage them.
• Lay the drain hose below the pipes.
Drain Hose
MOUNTING PLATE
Taping
Drain Cap
Piping route
For directions 1, 2 , 4 and 5, cut out the specific
zone without leaving any sharp edge.
(Keep the cut-out plate for possible future use.)
PLATE
Cut the plate
along notch.
Hook
MOUNTING PLATE
Tape
Pipes
Drain Hose
Insulation
Tape
Model 9000/12000 BTU
Model 18000/2400 BTU
Model 9000/12000 BTU
PLATE
PLATE
Piping holder
OM_AH-PN10 13GY_EN.indd Sec1:16
OM_AH-PN10 13GY_EN.indd Sec1:16
12/22/11 6:30:29 PM
12/22/11 6:30:29 PM