[2] TEST MODE
1. AH-129
Keep pushing the "AUX." buttons and supply the power, the system will go to the test mode. In this mode, the output of operation is switched by
pushing the ""AUX." button in the unit or the "OI" button in the remote controller. Normal outputs are shown in Table.
STEP No.
OUTPUT "-" : NO CHECK, "O" : ON, "X" : OFF
BUZZER
FAN
MOTOR
LOUVER
OUTDOOR
LED 101 LED 102 LED 103
LED 104
RED
YELLOW GREEN
BLUE
STEP0 BEEP2
O *1
O*2
O
X
X
X
X
*1 : 7
°
C<(ROOM TEMP.)<42
°
C
*2 : -2
°
C<(PIPE TEMP.)<45
°
C
STEP1 BEEP1
X
X
O
X
O
OPEN O
STEP2 BEEP1
O RPM
X
O
X
O
X
X
STEP3 BEEP1
O
*4
X
X
O
X
O
*4 : O --- POWER ON INVALIDITY
STEP4 BEEP1
O IC8
O
O
X
O
X
X
*4 : X --- POWER ON VALIDITY
STEP5 BEEP1
O
O
O
X
O
X
O
STEP6 BEEP1
X R.C.
X
O
X
O
X
X
STEP7 BEEP1
X
X
X
X
O
X
O
STEP8 BEEP1
X
X
O
X
O
X
X
STEP9 BEEP1
O
X
O
X
O
X
O
STEP10 BEEP1
O
O
O
X
X
CLOSE O
1. AH-MP14
STEP No.
OUTPUT "-" : NO CHECK, "O" : ON, "X" : OFF
BUZZER
FAN
MOTOR
LOUVER
OUTDOOR
PLASMA
CLUSTER
LED 101 LED 102 LED 103
LED 104
RED
YELLOW GREEN
BLUE
STEP0 BEEP2
O *1
O*2
O
O
X
X
X
X
*1 : 7
°
C<(ROOM TEMP.)<42
°
C
*2 : -2
°
C<(PIPE TEMP.)<45
°
C
STEP1 BEEP1
X
X
O
X
O
OPEN O
X
STEP2 BEEP1
O RPM
O
O
O
O
X
X
O
STEP3 BEEP1
O
*4
X
X
O
X
O
O
*4 : O --- POWER ON INVALIDITY
STEP4 BEEP1
O IC8
O
O
X
O
X
X
X
*4 : X --- POWER ON VALIDITY
STEP5 BEEP1
X
O
O
X
O
X
O
X
STEP6 BEEP1
X R.C.
X
O
X
O
X
X
X
STEP7 BEEP1
X
X
X
X
O
X
O
X
STEP8 BEEP1
X
X
O
X
O
X
X
X
STEP9 BEEP1
O
X
O
X
O
X
O
X
STEP10 BEEP1
O
O
O
X
X
CLOSE O
X
12
Содержание AH-129
Страница 7: ... 2 MICRO COMPUTER CONTROL SYSTEM 1 Electronic Control Diagram Indoor unit AH 129 AH MP14 7 ...
Страница 8: ...2 PRINTED WIRING DIAGRAM 2 1 Indoor AH 129 8 ...
Страница 9: ...2 2 Indoor AH MP14 9 ...
Страница 14: ...CHAPTER 4 TROUBLESHOOTING 14 ...
Страница 15: ...CHAPTER 4 TROUBLESHOOTING 15 ...
Страница 16: ...16 ...