2
AF-R100CX
AF-R120CX
Models
AF-R100CX
AF-R120CX
Cooling capacity
BTU/h
10000
12000
Moisture removal
Pints/h
2.7
3.3
ELECTRICAL DATA
Phase
Single
Rated frequency
Hz
60
Rated voltage
Volts
115
Rated current
Amps
9.0
11.5
Rated input
Watts
1000
1200
Power factor
%
97
91
EER
BTU/Wh
10.0
10.0
COMPRESSOR
Type
(Hermetically sealed rotary type)
Model, Remarks
44R251AC-AJS, 840 W
44B124HX1EF, 1000W
REFRIGERANT SYSTEM
Evaporator
Slit fin, Grooved tube, Ø 9.53 mm Hair pin
Condenser
Louver fin, Grooved tube, 7mm Hair pin
Control O.D. x I.D. x Length x Q'ty(mm)
Capillary tube 2.7 x 1.4 x 400 x 1
Capillary tube 2.7 x 1.2 x 800 x 2
Refrigerant volume R-22(OZ)
18.3(Factory charged)
19.4(Factory charged)
NET DIMENSIONS
Width Height Depth
inches(mm)
22-1/16(560) x 14-3/4(375) x 24-5/16(617)
Net Weight
lbs
83
85
GROSS DIMENSIONS
Width Height Depth
inches(mm)
25-25/32(655) x 18-29/32(480) x 27-7/8(708)
Gross Weight
lbs
94
96
FAN SYSTEM
Indoor side(Evaporator)
Centrifugal fan
Outdoor side(Condenser)
Propeller fan
Air flow rate(indoor side) CFM
(High/Med/Low) 304 / 254 / 223
(High/Med/Low) 318 / 254 / 219
OTHERS
Safety devices
Compressor: Overload relay
Fan motor: Internal thermal protector
Air filter
Polypropylene net
Power cord length
ft
4.3
Power plug type
125V, 15A
ELECTRICAL PARTS
Running capacitor
250V-60µF
370V-50µF
Fan capacitor
250V-6µF x 2
250V-6µF x 2
Thermistor
15k at 78˚F
Fan motor
ARS030ZUEA/SHP(MLA895)
ARS030ZUEA/SHP(MLA895)
Overload relay
MRA4789-9053
MRA98693-12007
SPECIFICATIONS