Cut the gasket to an appropriate length
and stuff it into the gap around the
mounting frame and the unit to seal
outside air. (Fig.8)
E-4
INSTALLATION INSTRUCTIONS
At this step, make sure the cabinet is
inclined approximately 1cm (3/8") to
the back (Fig.9).
If the cabinet is not properly inclined,
the water collected in the bottom tray
during operation will not drain properly
and may flow into the room where the
air conditioner is installed.
When drainage is necessary
If
water drainage is necessary in high
humidity district, or if you do not like the
splashing sound of the non-drain func-
tion, remove the rubber cap on the
bottom of the chassis. Cut the rubber
cap in cross, working from the bottom
and remove the rubber pieces with a
plier.(Fig.6)
A hose of an appropriate length have to
be attached to the drain tray's drain
outlet. (Fig.7)
(3)
(1)
4
(2)
Install the cabinet into the installation
opening.(Fig.8)
Secure the cabinet to the mounting
frame using the 9 long gold screws.
(2.5cm/1"). (Fig.8)
Chassis
Rubber cap
Fig.6
Fig.7
Cabinet
Drain tray
Cabinet
Fig.8
Gasket
WARNING:
cabinet
mounting
frame
incline backwards about 1cm
(3/8")
Fig.9
Fig.5
Drain tray
Cabinet
Attach the provided drain tray to the
cabinet in case drainage becomes nec-
essary. Use the 2 short gold screws
(1.2cm/0.5") to fix it. (Fig.5)
3