AY-X36RU
AE-X36RU
33
DISASSEMBLY PROCEDURE
Be sure to turn off the circuit breaker before disassembly procedure. When reassembling the unit after repairing, be sure to install
screws to their original positions.
The screws used are not the same in specifications such as corrosion-resistant treatment, tip shape and length.
After the air conditioner is repaired or parts are replaced, measure insulation resistance of the equipment using an insulation resist-
ance meter. If the measured resistance is lower than 1 MW, inspect parts and repair or replace defective parts.
[1] INDOOR UNIT
1.
Before disassembly of the unit.
Axonometric drawing for the completeunit.
2.
Remove the filters.
1) Open the panel.
panel
2) Remove the two (2) filters.
filter
3.
Remove the display.
Remove the two (2) screws fixing display, and then remove
the display with lead wire.
Display
Lead wire
4.
Remove the panel.
Pull the hooks at both sides slightly, and then remove the
panel.
Hook
Panel
5.
Remove the horizontal louver.
Remove the axial bush on the horizontal louver, and then
remove the horizontal louver.
Horizontal louver
6.
Remove the top cover of the electric box.
1) Remove the screw fixing the top cover of the electric
box.
Screw
2) Remove the top cover of the electric box.
Top cover of
the electric box
7.
Remove the front case.
1) Remove the four (4) screw caps on the front case.
Screw cap