10
36U-F510
Focus Adjustment
1. Receive a good local channel.
2. Adjust the VR-1 (upper knob) and VR-2 (middle knob)
of the flyback transformer to make the image as fine
as possible.
C. C Display Position Adjustment
1. Receive the lion head pattern signal.
2. Select "EX2" to display the text box.
3. Adjust the "EX2" bus data to let the text box displayed
in the center.
Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D03" for V-size.
3. Adjust the "D03" bus data to get the proper V-size.
4. For V-linearity adjustment, select data bus "D05" and
adjust to get the proper vertical linearity.
Note: Aging for 10 min before adjustment. After the
adjustment of V-center and V-size, re-
adjustment for this V-line.
Vertical Phase Adjustment
1. Enter the service mode and select the service
adjustment "D01".
2. Adjust "D01" data value so that picture is centered.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D02".
3. Adjust "D02" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "EX2".
3. A black text box appears on the screen. (see
Figure
B. )
4. Adjust "EX2" data value so that text box is positioned
in the center of the screen.
Horizontal-Size Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D04" for H-size.
3. Adjust the "D04" bus data to get the proper H-size.
EW-Parabola
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D07" for EW parabola.
3. Adjust the "D07" bus data to get the proper vertical
straight line for both left and right side.
EW-Trapezium
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D08" for EW-Trapezium.
3. Adjust the "D08" bus data to get the best position
display.
EW-Corner
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D09" for EW-Corner.
3. Adjust the "D09" bus data to get the best linearity for
4 corner points.
Other Adjustments
1. Enter the service mode.
2. Adjust the following data values as listed below.
Figure B.
SERVICE ADJUST DATA(Hex)
POSITION ITEM
OP1 OPTION1
F5
OP2 OPTION2
18
OP3 OPTION3
0F
DISPLAY OF TEXT BOX
TEXT BOX
A
B
| A-B | / 2
SPEC INSPECTION:| A-B | / 2 <
= 5mm
Содержание 36u-f510
Страница 12: ...12 36U F510 6 5 4 3 2 1 A B C D E F G H MODEL 36U F500 CHASSIS LAYOUT ...
Страница 13: ...13 36U F510 6 5 4 3 2 1 A B C D E F G H MODEL 36U F500 BLOCK DIAGRAM ...
Страница 15: ...16 36U F510 15 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H MODEL 36U F510 SCHEMATIC DIAGRAM MAIN 1 Unit ...
Страница 16: ...18 36U F510 17 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H MODEL 36U F510 SCHEMATIC DIAGRAM MAIN 2 Unit ...
Страница 17: ...20 36U F510 19 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM AV Unit ...
Страница 18: ...21 36U F510 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM DF MODULE Unit ...
Страница 19: ...22 36U F510 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit ...
Страница 20: ...36U F510 6 5 4 3 2 1 A B C D E F G H 23 SCHEMATIC DIAGRAM MTS MODULE Unit ...
Страница 22: ...25 36U F510 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Wiring Side ...
Страница 23: ...26 36U F510 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side ...
Страница 24: ...27 36U F510 6 5 4 3 2 1 A B C D E F G H PWB C AV Unit Chip Parts Side PWB C AV Unit Wiring Side ...
Страница 25: ...28 36U F510 6 5 4 3 2 1 A B C D E F G H PWB H DF MODULE Unit Wiring Side ...