CHAPTER 5.
TROUBLE SHOOTING FLOWCHART
[1] TROUBLE SHOOTING FLOWCHART
NO RASTER
Blown out.
Replace the fuse.
Check IC701, D701 and
C705.
The fuse is blown out again.
Does horizontal circuit
oscillate ?
Check T701 pin (17) voltage
(Approx. 310V at 220V AC)
Check F701.
Check Secondary Main+B
(Approx. 130V)
Check CRT connector K-
wire and the signal on it.
Check Q601 and Q602.
Check 185V
Bias on
CRT board.
Check
IC801.
Checking the
protector circuit.
Check Q752 for 8V regulator
circuit and Q751, Q754 for
5V regulator circuit.
Check D751, IC702, D750
and IC703.
Check R701.