18-1
18-2
H-VCO
V21
STEP RANGE
0-7
I
2
C CONTROL
OPTION SET UP, BUS SET UP
NO SIGNAL (RASTER) CONDITION
AC 230V
IC 801 PIN 11
(MANUAL ADJ)
1) GO TO SERVICE MODE,
2) GO TO SERVICE DATA V21, ADJ UNTIL FREQ AS BELOW
(SELF ADJ)
1) GO TO SERVICE MODE,BY SELECTING THE SERVICE DATA V21
2) PRESS THE R/C TO OPERATE AUTO H-VCO,OSD APPEAR "OK" AT
SCREEN
3) IF APPEAR "NG" PLS REPEAT STEP2
[CHECKING SPEC]
FREQ = 15.735 ± 0.2 KHz
SYMBOL
REVISED CONTENT,
ADJUSTMENT
ITEM
ADJUSTMENT
POSITION
CONTROL
PRE-ADJUST
REQUIREMENT
CONTENT
INPUT
CONDITION
OUTPUT
ADJUSTMENT
PROCEDURE
HISTORY
OF REVISION
ADJUSTMENT
ITEM
ADJUSTMENT
POSITION
CONTROL
PRE-ADJUST
REQUIREMENT
CONTENT
INPUT
CONDITION
OUTPUT
ADJUSTMENT
PROCEDURE
HISTORY
OF REVISION
(AT SELF ADJUSTMENT MODE)
1) GO INTO SERVICE MODE, BY SELECTING THE SERVICE DATA V10
2) PRESS THE R/C FOR AUTO PIF-VCO KEY, OSD APPEAR "OK" AT
SCREEN
3) IF APPEAR "NG" PLS REPEAT STEP 2
(AT MANUAL ADJUSTMENT MODE)
1) GO INTO SERVICE MODE, BY SELECTING THE SERVICE DATA V10
2) ADJUST THE DATA UP/DOWN UNTIL IC801 PIN 2 VOLTAGE BECOME
AS SPECIFIED BELOW
PIF-VCO
V10
STEP RANGE
0~63
I
2
C CONTROL
OPTION SET UP, BUS SET UP
NO SIGNAL (RASTER) CONDITION
AC 230V
CONFIRMATION ON CRT DISPLAY (AUTO), IC801 PIN 2 VOLTAGE (MANUAL).
[CHECKING SPEC]
2.5 ± 0.5 V DC (CHECKING SPEC : 2.50 ± 1.5V)
SYMBOL
REVISED CONTENT,
14V-R70M
Содержание 14V-R70M
Страница 24: ...24 WAVEFORMS 14V R70M ...
Страница 25: ...25 6 5 4 3 2 1 A B C D E F G H CHASSIS LAYOUT 14V R70M DUNTKD373WE PR701 ...
Страница 26: ...26 6 5 4 3 2 1 A B C D E F G H CRT BLOCK DIA GRAM 14V R70M ...
Страница 28: ...28 14V R70M 10 11 12 13 14 15 16 17 18 19 FILT HLF V HOLD SAV L VOL FR P MONO POW ...
Страница 30: ...220 270 R609 27 1 2 W C720 1u 50V 22 0 0022 ...
Страница 31: ...32 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit 14V R70M ...
Страница 34: ...35 6 5 4 3 2 1 A B C D E F G H 14V R70M PWB B CRT Unit Wiring Side ...
Страница 43: ...I NAKAMURA M GABIT A UGALDE A CALING 1 Noted Approved Checked Prepared Issue No Date Received by ...