background image

12

8

7

10

9

6

5

4

3

2

1

A

C

D

E

F

G

H

13L-M100/150
CL13M10/15
14ML10

6

5

4

3

2

1

A

C

D

E

F

G

H

CHASSIS LAYOUT

PWB-B

PWB-A

Содержание 13L-M100/150

Страница 1: ... MANUAL This document has been published to be used for after sales service only The contents are subject to change without notice MODELS POWER INPUT 120 V AC 60 Hz POWER RATING 69 W PICTURE SIZE 580cm2 89 8sq inch CONVERGENCE Magnetic SWEEP DEFLECTION Magnetic FOCUS Hi Bi Potential Electrostatic INTERMEDIATE FREQUENCIES Picture IF Carrier Frequency 45 75 MHz Sound IF Carrier Frequency 41 25 MHz C...

Страница 2: ...libration of this meter should be checked periodically 3 High voltage should always be kept at the rated value no higher Operation at higher voltages may cause a failure of the picture tube or high voltage circuitry and also under certain conditions may produce radiation in exceeding of desirable levels 4 When the high voltage regulator is operating properly there is no possibility of an X radiati...

Страница 3: ...capacity networks mechanical insulators and etc 3 To be sure that no shock hazard exists check for leakage current in the following manner Plug the AC cord directly into a 120 volt AC outlet Do not use an isolation transformer for this test Using two clip leads connect a 1 5k ohm 10 watt resistor paralleled by a 0 15µF capacitor in series with all exposed metal cabinet parts and a known earth grou...

Страница 4: ...ipuler le tube image qu en porant des lunettes incassables et qu après avoir déchargé totalement la haute tension LIMITES DES RADIATIONS X ET DE LA HAUTE TENSION 1 Tout le personnel réparateur doit être instruit des instructions et procédés relatifs aux radiations X Le tube image seule source de rayons X dons les téleviseurs transistorisés n émet pourtant pas de rayons mesurables si la haute tensi...

Страница 5: ...s isolateurs mécaniques etc 3 S assurer qu il n y ait pas de danger d électrocution en vérifiant la fuite de courant de la facon suivante Brancher le cordon d alimentation directem ent à une prise de courant de 120V Ne pas utiliser de transformateur d isolation pour cet essai A l aide de deux fils à pinces brancher une résistance de 1 5 kΩ 10 watts en parallèle avec un condensateur de 0 15µF en sé...

Страница 6: ...6 13L M100 150 CL13M10 15 14ML10 LOCATION OF USER S CONTROL ...

Страница 7: ...If the operation of the horizontal oscillator does not stop in step 5 the circuit must be repaired before the set is returned to the customer HIGH VOLTAGE CHECK High voltage is not adjustable but must be checked to verify that the receiver is operating within safe and efficient design limitations as specified checks should be as follows 1 Connect an accurate high voltage meter between ground and a...

Страница 8: ...he normal mode Use the reset function in the video adjustment menu to ensure customer controls are in their proper reset position 2 Service number selection Once in the service mode press the Ch up or Ch down button on the remote controller or at the set The service adjustment number will vary in increments of one from S01 to OP Select the item you wish to adjust 3 Data number selection Press the ...

Страница 9: ...1 03 00 NORMAL 01 No Y 03 No VERTICAL S20 ENERGY SAVE OFFSET 20 00 3F Must be set to 23 S21 D D E OFFSET 03 00 1F Must be set to 03 S22 OSD SETUP 00 00 03 Must be set to 00 S23 TUNER SETUP 00 00 01 Must be set to 00 OP OPTION 30 00 FF Must be set to 02 IC2001 IC2101 X CRT X IC201 Data is stored in IC2101 Adjust items related to picture tube only Table A Holding down both the Ch up down buttons on ...

Страница 10: ...7 volts on the digital voltmeter 6 Adjust the master screen control until the raster darkens to the point where raster is barely seen 7 Adjust the service adjustments S11 red S12 green and S13 blue to obtain a good grey scale with normal whites at low brightness level 8 Select the service adjustment S19 and reset data to 00 Select the service adjustment S03 and reset data to obtain normal color le...

Страница 11: ...nter the service mode and select the service adjustment S18 3 A black text box appears on the screen see Figure B below 4 Adjust S18 data value so that text box is positioned in the center of the screen Figure B 3 58MHz Trap Adjustment 1 Receive a good local channel 2 Enter the service mode and select the service adjustment S16 3 This is a two position adjustment 00 is ON 01 is OFF 4 Adjust data v...

Страница 12: ...12 8 7 10 9 6 5 4 3 2 1 A B C D E F G H 13L M100 150 CL13M10 15 14ML10 6 5 4 3 2 1 A B C D E F G H CHASSIS LAYOUT PWB B PWB A ...

Страница 13: ...13 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM ...

Страница 14: ... picture unless otherwise indicated 2 All voltages measured with 1000µ V B W or Color signal WAVEFORM MEASUREMENT CONDITIONS 1 Photographs taken on a standard gated color bar signal the tint setting adjusted for proper color The wave shapes at the red green and blue cathodes of the picture tube depend on the tint color level and picture control 2 indicates waveform check points See chart waveforms...

Страница 15: ...15 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit Ë13L M100 150 CL13M10 15 Ë14ML10 ...

Страница 16: ...9 6 5 4 3 2 1 A B C D E F G H 13L M100 150 CL13M10 15 14ML10 MODELS 13L M100 150 CL13M10 15 SCHEMATIC DIAGRAM MAIN Unit PWB A DUNTK9529WEW1 13L M100 150 DUNTK9529WEW3 CL13M10 15 13L M100 CL13M10 13L M150 CL13M15 ...

Страница 17: ...17 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 ...

Страница 18: ...18 8 7 10 9 6 5 4 3 2 1 A B C D E F G H 13L M100 150 CL13M10 15 14ML10 MODEL 14ML10 SCHEMATIC DIAGRAM MAIN Unit ...

Страница 19: ...19 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 ...

Страница 20: ...20 8 7 10 9 6 5 4 3 2 1 A B C D E F G H 13L M100 150 CL13M10 15 14ML10 PRINTED WIRING BOARD ASSEMBLIES PWB A MAIN Unit Wiring Side 6 5 4 3 2 1 A B C D E F G H ...

Страница 21: ...21 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 PWB A MAIN Unit Chip Parts Side 6 5 4 3 2 1 A B C D E F G H ...

Страница 22: ...22 8 7 10 9 6 5 4 3 2 1 A B C D E F G H 13L M100 150 CL13M10 15 14ML10 6 5 4 3 2 1 A B C D E F G H PWB B CRT Unit Chip Parts Side PWB B CRT Unit Wiring Side ...

Страница 23: ...ement et correctement remplie veuillez fournir les renseignements suivants 1 NUMERO DU MODELE 2 NO DE REF 3 NO DE PIECE 4 DESCRIPTION in CANADA Contact SHARP Electronics of Conada Limited Phone 416 890 2100 MARQUE SECTION LIVRAISON DES PIECES DE RECHANGE MARQUE PIECES RELATIVE AUX RAYONS X PICTURE TUBE çå V101 VB370BVBK1S S R CRT DY601 H0143PE BZ or VB370BVBK1U S CRT DY601 H0143PE or VB34JFQ90X S ...

Страница 24: ...Z å D762 RH DX0441CEZZ J Diode AC or RH DX0110CEZZ D763 VHD1SS119 1 J Diode AB D901 RH EX0630GEZZ J Zener Diode 9 1V AA D902 RH EX0630GEZZ J Zener Diode 9 1V AA D2001 VHD1SS119 1 J Diode AB PACKAGED CIRCUITS å PR701 RMPTP0026CEZZ J Packaged Circuit AF X801 RCRSB0205CEZZ R Crystal AF or RCRSB0001PEZZ FILTERS CF301 RFiLC0403CEZZ J Ceramic Filter AE or RFiLC0029TAZZ CF401 RFiLC0013CEZZ J Ceramic Filt...

Страница 25: ...12 RC EZ0638CEZZ J 33 160V EL AG C751 VCEA0A1VW477M J 470 35V EL AB C754 VCEA0A1CW337M J 330 16V EL AC C755 VCEA0A1CW107M J 100 16V EL AC C756 VCEAGA1CW108M J 1000 16V EL AD C757 VCQYTA1HM104K J 0 1 50V Mylar AC å C758 VCEAGA2EW106M J 10 250V EL AC C759 VCKYPA2HB102K J 1000p 500V Ceramic AA C760 VCEAGA1CW108M J 1000 16V EL AD C801 VCQYTA1HM223K J 0 022 50V Mylar AB C802 VCEA0A1HW474M J 0 47 50V EL...

Страница 26: ...2AL102J J 1 0k 1 10W M Film AA R602 VRD RA2EE820J J 82 1 4W Carbon AA å R603 VRS VV3LB270J J 27 3W M Ox AB R605 VRN MD2AL332J J 3 3k 1 10W M Film AA R606 VRD RA2BE102J J 1 0k 1 8W Carbon AA R608 VRD RA2BE101J J 100 1 8W Carbon AB R609 VRD RA2BE331J J 330 1 8W Carbon AA å R610 VRS VV3DB391J J 390 2W M Ox AA R620 VRD RA2BE473J J 47k 1 8W Carbon AA R621 VRN MD2AL682J J 6 8k 1 10W M Film AA R631 VRN M...

Страница 27: ...J Plug 6 pin K AB P651 QPLGN0361CEZZ J Plug 3 pin AB P701 QPLGN0207CEZZ J Plug 2 pin M AA P751 QPLGN0461CEZZ J Plug 4 pin YBN AB P2001 QPLGN0561CEZZ J Plug 5 pin AB RMC2601 RRMCU0227CEZZ J R C Receiver AK or RRMCU0222CEZZ RDA501 PRDAR0218PEFW R Heat Sink IC501 AD RDA701 PRDAR0237PEFW R Heat Sink IC701 AK TP701 QLUGP0102PEZZ R Lug AA PZETM0016CEZZ J Insulator AB LX BZ3049GEFD J Screw AA LX BZ3100CE...

Страница 28: ...VCKYCY1HF103Z J 0 01 50V Ceramic AA C205 VCEA0A1HW474M J 0 47 50V EL AB C206 VCEA0A1CW227M J 220 16V EL AC C207 VCKYCY1HF103Z J 0 01 50V Ceramic AA C208 VCEA0A1HW474M J 0 47 50V EL AB C209 VCKYCY1HB222K J 2200p 50V Ceramic AA C210 VCKYCY1HB102K J 1000p 50V Ceramic AA C302 VCCCCY1HH330J J 33p 50V Ceramic AA C303 VCKYCY1HB472K J 4700p 50V Ceramic AA C304 VCEA0A1HW225M J 2 2 50V EL AB C305 VCKYPA1HB1...

Страница 29: ...Ox AA RJ35 VRS CY1JF000J J 0 1 16W M Ox AA RJ39 VRS CY1JF000J J 0 1 16W M Ox AA RJ40 VRS CY1JF000J J 0 1 16W M Ox AA RJ46 VRS CY1JF000J J 0 1 16W M Ox AA RJ49 VRS CY1JF000J J 0 1 16W M Ox AA RJ52 VRS CY1JF000J J 0 1 16W M Ox AA RJ54 VRS CY1JF000J J 0 1 16W M Ox AA RJ55 VRS CY1JF000J J 0 1 16W M Ox AA RJ57 VRS CY1JF000J J 0 1 16W M Ox AA RJ59 VRS CY1JF000J J 0 1 16W M Ox AA RJ62 VRS CY1JF000J J 0 1...

Страница 30: ...0J J 75 1 16W M Ox AA R906 VRS CY1JF102J J 1 0k 1 16W M Ox AA R925 VRS CY1JF104J J 100k 1 16W M Ox AA R961 VRS CY1JF101J J 100 1 16W M Ox AA R962 VRS CY1JF101J J 100 1 16W M Ox AA R2001 VRD RA2BE102J J 1 0k 1 8W Carbon AA R2002 VRS CY1JF103J J 10k 1 16W M Ox AA R2006 VRS CY1JF103J J 10k 1 16W M Ox AA R2007 VRD RA2BE223J J 22k 1 8W Carbon AA R2008 VRD RA2BE224J J 220k 1 8W Carbon AA R2009 VRS CY1JF...

Страница 31: ... AA LX TZ3004CEFD J Screw AA PWB A DUNTK9529WEW5 14ML10 MAIN UNIT Continued TRANSISTORS Q852 VS2SC2229O 1E J 2SC2229 O AD Q854 VS2SC2229O 1E J 2SC2229 O AD Q856 VS2SC2229O 1E J 2SC2229 O AD Q881 VS2SA1266 Y 1 J 2SA1266 Y AA or VS2SA1015 Y 1 DIODES D881 VHD1SS119 1 J Diode AB D882 VHD1SS119 1 J Diode AB D885 VHD1SS119 1 J Diode AB COIL L851 VP DF151K0000 J Peaking 150µH AB CAPACITORS EL Electrolyti...

Страница 32: ...4ML10 QACCD3060CESA å ACC701 QACCD3060CESB J AC Cord 13L M150 CL13M15 AR QCNW 2105PEZZ R Connecting Cord AF QCNW 2106PEZZ R Connecting Cord AE QCNW 2107PEZZ R Connecting Cord AE QANTR0022PEZZ R Rod Antenna AP CL13M10 15 QANTR0018PEZZ R Rod Antenna 14ML10 AQ SP1 VSP0080PBK58A J Speaker 8 ohm AL MISCELLANEOUS PARTS SUPPLIED ACCESSORIES RRMCG1324CESA J Infrared R C Unit AT 13L M100 CL13M10 RRMCG1324C...

Страница 33: ...t No Description Code 13L M100 150 CL13M10 15 14ML10 PACKING OF THE SET REAR Use tapes to fix the packing case Packing Case FRONT Buffer Material Wrapping Paper Polyethylene Bag Operation Manual Guarantee Card Batteries MARK Not Replacement Items ...

Страница 34: ...rt of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION AV Systems Group Quality Reliability Control Center Yaita Tochigi 329 2193 Japan TQ0637 S Apr 1999 Printed in Japan SY KG ...