11
13L-M100/150
CL13M10/15
14ML10
Sub-Brightness Adjustment
1. Receive a good local channel.
2. Make sure the customer brightness control is set to
center position.
3. Enter the service mode and select the service
adjustment "S04".
4. Adjust "S04" data value to obtain normal brightness
level.
Vertical-Size Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S09".
3. While observing the top and bottom of the screen,
adjust "S09" data value to proper vertical size.
Vertical Phase Adjustment
1. Enter the service mode and select the service
adjustment "S06".
2. Adjust data value to "00"~"03" so that picture is
approximate center.
Note: This must be set "00"~"03" when adjust
another data retrace line will be appear.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S07".
3. Adjust "S07" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S18".
3. A black text box appears on the screen. (see Figure
B. below)
4. Adjust "S18" data value so that text box is positioned
in the center of the screen.
Figure B.
3.58MHz Trap Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S16".
3. This is a two position adjustment, "00" is ON, "01" is
OFF.
4. Adjust data value to "00" for normal viewing.
Sharpness, Audio Balance, Energy Save
Offset, DDE Offset, OSD Setup, Tuner
Setup and Option Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustments "S05" for sharpness, "S17" for balance,
"S20" for energy save offset, "S21" for DDE offset,
"S22" for OSD setup, "S23" for tuner and "OP" for
option.
»
Sharpness Adjustment
3. Adjust data value to "24" (center of data range) for
sharpness adjustment.
»
Audio Balance Adjustment
4. Adjust data value to "20" (center of data range) for
Audio balance adjustment.
»
Energy Save Offset Adjustment
5. Adjust data value to "23".
»
DDE Offset Adjustment
6. Adjust data value to "03".
»
OSD Setup Adjustment
7. Adjust data value to "00".
»
Tuner Setup Adjustment
8. Adjust data value to "00".
»
Option Adjustment
9. Adjust data value to "02".
Содержание 13L-M100/150
Страница 6: ...6 13L M100 150 CL13M10 15 14ML10 LOCATION OF USER S CONTROL ...
Страница 13: ...13 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM ...
Страница 17: ...17 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 ...
Страница 19: ...19 17 16 19 18 15 14 13 12 11 10 13L M100 150 CL13M10 15 14ML10 ...