11
0 8 0 0 8 6 2 0 4 5 3
CHECK FOR BLOCKAGES
REMOVE AND INSPECT:
1
HANDHELD AND TUBE
a
Remove the tube from the handheld portion and check all dust cup intake openings.
b
Remove the floor nozzle from the tube and check the tube for blockages.
2
BOTTOM OF FLOOR NOZZLE
c
Use a coin to unlock the three locks on the bottom of the floor nozzle.
d
A portion of the base is removable to allow for better access to the brush roll and exposure to the airway. Shine a flashlight from the bottom to check for
possible blockage in the airway.
e
Remove any string, carpet fibres or hair that may be wrapped around the brush roll. There is a groove on the brush bar that allows a pair of scissors to cut
across it to loosen up the debris.
f
To reassemble, replace base by lining it up along the front of the nozzle. Push down to snap into place. Lock the three locks.
MAINTENANCE
Make sure unit is off
and cord unplugged.
a
b
b
f
e
c
c
c
d