97-727, 96-721 • REV. 4/06
OPERA
T
OR’S MANU
AL
PRESSURE W
ASHER
8
OPERATING INSTRUCTIONS
STEP 1:
Connect garden hose to the
cold water source and turn water on
completely. Never use hot water.
STEP 2:
Trigger the spray gun to
eliminate trapped air then wait for a
steady flow of water to emerge from
the spray nozzle.
Cold
Water
Source
Garden
Hose
WARNING! Never replace
nozzles without engaging the
safety latch on the spray gun trig-
ger.
The five color-coded quick connect nozzles provide a wide array of spray
widths from 0° to 45° and are easily accessible when placed in the conve-
nient rubber nozzle holder, which is provided on the front of the machine.
NOTE:
For a more gentle rinse, select the white 40° or green 25° nozzle.
To scour the surface, select the yellow 15° or red 0° nozzle. To apply deter-
gent select the black nozzle.
NOZZLES
Safety
Latch
STEP 3:
Connect machine to ad-
equate power source. Push reset
button on GFCI.
STEP 4:
Turn machine on.