97-727, 96-721 • REV. 4/06
7
PRESSURE W
ASHER
OPERA
T
OR’S MANU
AL
ASSEMBLY INSTRUCTIONS
STEP 1:
Attach the high pressure
hose to the spray gun using teflon
tape on hose threads.
STEP 3:
Release the coupler col-
lar and push the nozzle until the
collar clicks. Pull the nozzle to
make sure it is seated properly.
STEP 5:
Connect the high pressure
hose to the pump discharge fitting.
Push coupler collar forward until
secure.
STEP 2:
Pull the spring-loaded col-
lar of the wand coupler back to in-
sert your choice of pressure nozzle.
STEP 6:
Connect garden hose to
the cold water source.
STEP 7:
Check inlet filters, remove
debris, then connect the garden
hose to pump water inlet.
CAUTION: Do not run the pump
without water or pump damage
will result.
Safety
Latch
Spray
Gun
High Pressure
Hose
Wand
Coupler
Pressure
Nozzle
Pressure
Nozzle
Wand
Coupler
Coupler
Collar
Pump
Discharge
Fitting
High
Pressure
Hose
Cold
Water
Source
Garden
Hose
Pump
Water Inlet
Garden
Hose
Coupler Collar
DipStick
STEP 4:
Remove shipping cap and
install oil dipstick. Check pump oil
level by using dipstick or observe oil
level in oil window (if equipped). Use
30 wt. non detergent oil.