AFF/D 135
12-2-2015
-2-
Matt Asselman
2
TECHNICAL DATA
type
AFF/D 135
Assembly
Control unit
Max.
2
Upper heating element
Max
2
Pressure bars
2
Electrical
Control unit
Voltage
220
–
240 V AC
Power
520VA
Fuse
2,5 AT x2
Timer unit
Voltage
220
–
240 V AC
Power
5VA
Fuse
2,5 AT x2
connection
CEE 7/4 16A 2P+A
Network connection
CEE 7/4 16A 2P+A
Network circuit breaker
Max. 16 A
Pneumatic
Air
Unlubricated clean dry air
Maximum
6 bar
Minimum
5 bar
Operating pressure
6 bar
Coupling
Quick action coupling
Mechanical
Gradation of stop
0-500 mm
dimensions
[LxWxH]
850 x 1510 x 380 mm
weight
200 Kg
Functional
Bending width
1350 mm
Sheet thickness
0,2 - 1 mm
Temperature element
Max
220
◦
C
Ambient
Temperature
18-30
C
Humidity of the air
50-80 % (no condensed)
Miscellaneous
set of socket screws keys
1 set [1½, 3, 5 mm]
Spare fuse
4 x [6.3x32 2,5 AT]