SCM-MZ-LC NOT LIGHTING UP
When power is first applied to the lighting controller, the
box will flash blue very briefly.
Once it receives a valid control input from a connected
controller it will stay blue continuously. If it is not light-
ing up please double check for correct orientation and
reseat the SC-NET cable.
SHADOW-NET
®
LIGHTS WILL OCCASIONALLY
LOCK UP AND STOP RECEIVING MESSAGES
This indicates that there is a noise issue on the
Shadow-NET
®
communication lines. Typically this is
caused by insufficient gauge wire feeding one or more
Shadow-NET
®
connected lights.
MY SHADOW-NET
®
LIGHTS STAY ON
If the connected Shadow-NET
®
lights are not turning
off at initial power up then there is a challenge with the
Shadow-NET
®
connection.
Check the orange and yellow wire connections are not
reversed and are fully connected.
TROUBLESHOOTING
MFD CONNECTION TROUBLESHOOTING
MY SYSTEM IS NOT CONNECTING:
Remove 4 screws on top of SCM-MFD-BRIDGE. Verify
that the blue power light is on. This indicates a bad con-
nection on the 4 pin cable from the lighting controller
Verify that the red and green communication lights
are coming on and blinking. This will verify that the
Ethernet connection is good, and communication is
established.
MUSIC SYNC NOT WORKING
Verify that an appropriate 3.5mm stereo jack is being
used and that there is a usable signal.
If a separate output zone is used, verify that the output
is enabled and the output is set to a usable volume.
It is not recommended to use a subwoofer output, as
certain sync modes require the full audio range.
MY SYSTEM HAS A "BOOT LOADER ERROR"
This is typically a problem with multi-screen installation
and indicates that a POE isolator is needed.