![Shadin Avionics AIS-380 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/shadin-avionics/ais-380/ais-380_installation-manual_1251541019.webp)
M833811-00
Shadin Avionics
INSTALLATION MANUAL
AIS-380 FUEL FLOW ADAPTER
Rev: C
P/N 833811-00
Page: 19 of 20
Shadin Avionics
6831 Oxford Street
St. Louis Park, MN 55426
USA
4
ENVIRONMENTAL QUALIFICATION FORM (EQF)
NOMENCLATURE:
AIS-380 FUEL FLOW ADAPTER
TYPE/MODEL/PART NO:
833811-00
TSO NUMBER:
TSO-C44c INCOMPLETE SYSTEM
MANUFACTURER'S SPECIFICATION AND/OR OTHER APPLICABLE SPECIFICATION
:
Report SD-110037, RTCA/DO-160F
RTCA/DO-160F QUALIFICATION:
[A4X]BBB[R(B,B1) U2(F,F1)]XXXXXXZ[BXX]AZ[CC][RR]M[XXJ33]XXAX
MANUFACTURER
: Shadin Avionics
ADDRESS:
6831 Oxford Street, St. Louis Park, Minnesota 55426
CONDITIONS
SECTION
DESCRIPTION OF TESTS CONDUCTED
Temperature and Altitude
4.0
A4X
Low Temperature (Operating)
High Temperature (Operating)
Altitude
Decompression
Overpressure
4.0
-
40˚C [See remarks (1)
]
+70˚C
42,000ft [See remarks (2)]
42,000ft [See remarks (2)]
-15,000ft
Temperature Variation
5.0
Tested to Category B
Humidity
6.0
Tested to Category B
Operational Shock and Crash Safety
7.0
Tested to Category B
Vibration
8.0
Tested to Category R(B,B1)U2(F,F1)
Explosion
9.0
Identified as Category X. Not tested
Waterproofness
10.0
Identified as Category X. Not tested
Fluids Susceptibility
11.0
Identified as Category X. Not tested
Sand and Dust
12.0
Identified as Category X. Not tested
Fungus
13.0
Identified as Category X. Not tested
Salt Spray
14.0
Identified as Category X. Not tested
Magnetic Effect
15.0
Tested to Category Z
Power Input
16.0
Tested to Category BXX
Voltage Spike
17.0
Tested to Category A
Audio Frequency Susceptibility
18.0
Tested to Category Z
Induced Signal Susceptibility
19.0
Tested to Category CC
Radio Frequency Susceptibility
20.0
Tested to Category RR
Radio Frequency Emission
21.0
Tested to Category M
Lightning Induced Transient Susceptibility
22.0
Tested to Category XXJ33
Lightning Direct Effects
23.0
Identified as Category X. Not tested
Icing
24.0
Identified as Category X. Not tested
Electrostatic Discharge
25.0
Tested to Category A.
Fire, Flammability
26.0
Identified as Category X. Not tested
REMARKS:
(1)
The 833811-00 was tested to -40°C, beyond the normal A4 category temperature limits.
(2) The 833811-00 was tested to +42,000 ft., beyond the normal A4 category altitude and decompression limits.