![Shadin Avionics AIS-380 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/shadin-avionics/ais-380/ais-380_installation-manual_1251541016.webp)
M833811-00
Shadin Avionics
INSTALLATION MANUAL
AIS-380 FUEL FLOW ADAPTER
Rev: C
P/N 833811-00
Page: 16 of 20
Shadin Avionics
6831 Oxford Street
St. Louis Park, MN 55426
USA
Below is an example of the result of a disconnected serial cable. Note the box next to Software Version
remains yellow in color:
(6) Select the desired speed for each ARINC channel.
(7) Under Fuel Flow Parameters, select Enabled.
(8) Select Use 422 Port Parameters if this is an AIS-380 Bell 412 EPI Helicopter installation per Figure 4.
For all other installations, leave this box unchecked.
(9) Select the appropriate Engine Type from the drop-down list: Single Engine or Twin Engine.
(10) Enter a Fuel Flow K Factor number between 4000 and 100000 for each applicable engine. The K
Factor can normally be found on the fuel flow transducer.
(11) Enter a Fuel Density number between 0.00 and 10.00. Fuel Density examples are 5.80 for AvGas and
6.70 for Jet A.