DOCUMENT
943200-11 ETM RECORDER
Control
SC1
INSTALLATION MANUAL
Revision
–
M943200-11
Page: 7 of 17
SHADIN AVIONICS
www.shadin.com
Customer Service: (952) 836-2269
3
INSTALLATION
3.1
LIMITATIONS
The conditions and tests required for TSO approval of this article are minimum performance standards. It is
the responsibility of those installing this article either on or within a specific type or class of aircraft to
determine that the aircraft installation conditions are within the TSO standards. TSO articles must have
separate approval for installation in an aircraft. The article may be installed only if performed under 14 CFR
part 43 or the applicable airworthiness requirements
.
3.2
MOUNTING
The unit
may be mounted in any orientation in environments specified in the environmental categories,
Section 4.
The unit should be mounted according to Installation Drawing, P/N D943200-11.
3.3
ELECTRICAL CONNECTION
Table 1
lists the connector and pin number, signal name, and signal description of the electrical connections
for the unit.
Table 1: Electrical Connection
Connector &
Pin Number
Signal Name
Signal Description
Connection to Power Source
J1:8 PWR 28V
POWER 28VDC
J1:15 PWR GND
POWER GROUND
Serial Data
J1:12 RX RS-232
RECEIVE RS-232
J1:14 TX RS-232
TRANSMIT RS-232
J1:1 SIG GND
SIGNAL GROUND
Electrical connections listed in Table 1 are made through the use of the following
•
Mating connector
Standard 15 Pin Female D-SUB