CLEARING A JAM FROM THE TOOL

FASTENER JAMMED IN FASTENER DISCHARGE AREA:

Disconnect air tool from air hose.
Open the nozzle part, grab jammed fastener with pliers and remove.

FASTENER JAM INSIDE MAGAZINE:

Disconnect air tool from air hose.
Pull back on the magazine cover.
Open the nozzle part and remove jammed fastener.
Push the magazine cover forward until the latch catches.

CLEANING THE TOOL

Disconnect tool before cleaning and inspection. Correct all 
problems before placing the tool back in use.

 

NEVER USE PETROL OR OTHER FLAMMABLE LIQUIDS TO 
CLEAN THE TOOL. VAPORS IN THE TOOL WILL IGNITE 
AND CAUSE THE TOOL TO EXPLODE AND RESULT IN 
DEATH OR SERIOUS PERSONAL INJURY.

 
Remove tar build up with kerosene #2 fuel oil or fuel.
Dry off tool completely before use. 
DO NOT SOAK tool with cleaning solutions or damage may occur.

 

 WARNING   

 

 DANGER   

Содержание SAT402

Страница 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SAT402 FINE WIRE STAPLER...

Страница 2: ...6 16 FASTNER LENGTHS IN 1 4 5 8 SAFETY GUIDELINES Please read and fully understand the manual for information relating to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS Indicates an immedia...

Страница 3: ...handing the tool to another person 10 Never use tool if safety trigger or springs are inoperable missing or damaged Do not alter or remove safety trigger or springs Make daily inspections for free mov...

Страница 4: ...P SAFETY TOOL Disconnect the air supply from the tool Empty the magazine Make sure the trigger and the safety move up and down without sticking Connect the air supply to the tool Depress the safety ti...

Страница 5: ...l oil Attach a high flow quick connector fitting to the tool Empty the magazine Regulate the air pressure to obtain air pressure within the working pressure range at the tool Load fasteners into your...

Страница 6: ...e oiler is used manual lubrication through the air inlet is not required on a daily basis Many air tool users find it convenient to use an oiler to help provide oil circulation through the tool and in...

Страница 7: ...ener Push the magazine cover forward until the latch catches CLEANING THE TOOL Disconnect tool before cleaning and inspection Correct all problems before placing the tool back in use NEVER USE PETROL...

Страница 8: ...PAGE 8 PARTS DIAGRAM WWW SGS ENGINEERING COM...

Страница 9: ...PAGE 9 PARTS LIST...

Страница 10: ...Worn or damaged o rings or seals Tighten screws Install overhaul kit Tool does nothing or operates sluggishly Inadequate air supply Inadequate lubrication Worn or damaged O rings or seals Verify scre...