17
Connecting to control data
The device complies with the Digital MultipleX (DMX) communications protocol. It is controlled using a DMX control
device and must be connected to the data link using a DMX cable with a 5-pin DMX connector.
Connect the DMX in socket and out socket to the DMX data link. The device can feed control signals to another
device in a daisy chain using the built-in 0.5 m (20 in.) DMX-out cable.
Use only IP-rated XLR connectors when using the fixture outdoors.
Terminate the last device in the data link by connecting a 5-pin XLR DMX terminator to its DMX-out socket. A
terminator can be purchased from your cable or lighting supplier, or made by soldering a 120-ohm resistor between
pins 2 and 3 in a 5-pin XLR DMX connector.
Pin
Signal
1
Signal common
2
Data -
3
Data +
4
Not used
5
Not used