2 - Menu descriptions

2.1 Soft Patch

In this Menu, it's possible to assign the POWER LIGHT's physical channels (CHN) to the digital
channels available (ADDR). This creates a correspondence between the Dimmer output channel
and the channel that has to be controlled.
There are 512 channels available for use, i.e., those provided for by DMX standard, and they don't
necessarily have to be in succession.

For access to the 

Soft Patch

function, proceed as follows:

1.

Select 

SOFTPATCH

in the main menu;

2.

Press Enter to confirm the choice;

3.

Move the square brackets to the 

CHN

field and select the channel to be assigned;

selecting  

1>>

CHN1=ADDR; CHN2=ADDR+1;...;ADDR11=ADDR+11.

4.

Move the square brackets to the 

ADDR

field to assign the digital channel to the channel tha

has  just been selected;

5.

Repeat from point 3 to assign the other channels.

6.

Press 

Esc

to return to the main menu - the selected data are automatically updated.

2.2 Set Chn Mode (Channel Mode)

In this Menu, it's possible to choose the operating mode for each individual channel. It is in fact
possible to control the Power Light's channels independently or via a lighting control desk.
There are three operating modes available:

- FIX.

The output of channels set in this mode isn't controlled by a lighting control desk and

remains fixed on a value which can be set later.

- OFF.

The output of channels set in this operating mode stays off and cannot be controlled by a

lighting control desk

- EXT. 

(EXTERNAL) Output channels set in this mode can only be controlled by a lighting control

desk.

The standard factory setting is with all the channels in EXT.

For access to the 

Set Channel Mode

function, proceed as follows:

1.

Select the Channel Mode menu from the main menu;

<Main Menu     >

[Set chn mode  ]  

CHN   ADDR       

[1]      1      

<Main Menu     >

[Soft Patch    ]

www.audiovias.com

Содержание Powerlight 1212D

Страница 1: ...www audiovias com...

Страница 2: ...lammable liquids water or metal objects enter the unit Should any liquid be spilled on the unit disconnected the power supply to the unit immediately In the event of serious operating problems stop us...

Страница 3: ...manufacturers guarantee conditions Transport costs and related risks are borne by the unit s owner The guarantee is valid to all effects only on presentation of the guarantee certificate to the manufa...

Страница 4: ...6 RS 232 connection 11 1 3 7 Switching on 11 1 3 8 Using the microcomputer 12 1 3 9 Signaling of the display 13 1 3 10 menu 14 2 Description of the menu 14 2 1 Soft Patch 14 2 2 Set chn mode 15 2 3 Se...

Страница 5: ...in this manual may not be completely up to date If any doubts arise regarding the topics covered in this manual or should any further help be required our online services internet server www sgm it a...

Страница 6: ...n be controlled using a lighting control console or used a stand alone unit In fact it s possible to set the output level of the individual channels or create 4 Chases with up to 32 steps scenes in ea...

Страница 7: ...nnector 1 XLR 5 P female connector 1 2 3 Before installation Read the following warnings before beginning installation This unit is not intended for home use Disconnect the power supply before carryin...

Страница 8: ...t s cables is sufficient for the power absorbed by the unit Should it be necessary replace the fuses with others of the same type and value It s inadvisable to use adapters in line connectors or exten...

Страница 9: ...380V 50 60HZ 32Kw Max OUT IN DMX 512 Disconnect fixture before opening Non aprire prima di avere tolto la tensione CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE TO CONSULT THE MANUAL BEFORE EVERY OPE...

Страница 10: ...c use MAIN 3 N PE 380V 50 60HZ 32Kw Max OUT IN DMX 512 Disconnect fixture before opening Non aprire prima di avere tolto la tensione CH1 CH2 CH3 CH4 CH8 CH7 CH6 CH5 CH9 CH10 CH12 CH11 CONSULTARE IL MA...

Страница 11: ...ignal and cancel it The termination is made by soldering a 120 1 4 W resistor across pins 2 and 3 of the 5 pole male XLR connector see diagram 1 3 6 Connection RS 232 Good quality screened RG 58 50 co...

Страница 12: ...eck for any irregularities in the power supply and on the output Press ENTER to proceed to the Main Menu 1 3 8 Using the microcomputer 1 The menus are scrolled using the UP DOWN buttons 2 Press ENTER...

Страница 13: ...blinking writing NO SIGNAL MISSING R PHASE MISSING S PHASE MISSING T PHASE Dangerous message writing and display blinking at the same time OVERTEMP C HIGH TEMP C FANS FAILURE Fixture name over voltage...

Страница 14: ...PHASE OK S PHASE OK T PHASE OK T INT C F MISSING R PHASE MISSING S PHASE MISSING T PHASE OVER TEMP C HIGH TEMP C LN ST CHN LEV 1 1 ALL 255 FIXTURE NAME P1212 RESUME DEFAULT NO YES SET DEFAULT NO YES C...

Страница 15: ...5 Repeat from point 3 to assign the other channels 6 Press Esc to return to the main menu the selected data are automatically updated 2 2 Set Chn Mode Channel Mode In this Menu it s possible to choose...

Страница 16: ...el This is expressed as a decimal value of between 000 and 255 5 Repeat from point 3 to set the other channels 6 Press Esc to return to the main menu the selected data are automatically updated 2 4 Se...

Страница 17: ...lems In fact by selecting the channel on which there are doubts Power Light controls its efficiency allowing to vary its value from 0 to maximum output and switching off the channels not involved and...

Страница 18: ...to the main menu the selected data are updated automatically 2 7 Signal Monitor In this Menu it s possible to check the level of the signal for controlling the channels on input Only one channel can...

Страница 19: ...e Power Light In fact the following parameters are checked the presence or not of DMX signal on input any excess voltage on input correct operation of both fans the presence or not of RS 232 signal on...

Страница 20: ...nfirm the choice 5 At this point the following appears on the display LN Maximum number of steps ST Current step CHN Channel A AL LL Lset all the channels LEV light output level assigned to the channe...

Страница 21: ...ds LEV general light output level assigned to the CHASE 0 255 4 For the chase selected in the CHS field set the CROSS and SPEED times required and the general light level 5 Press ESC to confirm change...

Страница 22: ...signed to the chosen channel 5 Press the ESC button to return to the main menu the selected data are automatically updated 2 13 Set default This feature allow to customized the default parameters for...

Страница 23: ...onfirm the changes and return to the previous menu 2 15 Fixture name This feature allow to set the default parameter To access the programming function of the Fixture name menu proceed as follows 1 Se...

Страница 24: ...rs will cut off the channel 3 3 PROTECTION AGAINST INCORRECT CONNECTIONS The display will show the missing phase 4 Error messages Error messages are indicated by the display giving a long flash Should...

Страница 25: ...www audiovias com...