Please note:

 to ensure maximal stability, when the voltage is 120V, only five devices may be connected 

together in this manner! From the sixth device, please connect to power supply to get power for the second 
link; when the voltage is over 220V, only ten devices may be connected together in this manner! From the 
eleventh device, please connect to power supply to get power for the second link. 
 

DMX-512 connection with DMX terminator 

For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, 
such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of 
the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor 
connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the 
chain. Please see illustrations below. 
 
 

4

5

 

 
 

Projector DMX starting address selection 

All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture 
responds to the correct control signals. This digital starting address is the channel number from which the 
fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of 
this starting address is achieved by setting the correct number on the display located on the base of the 
device. 
 
You can set the same starting address for all fixtures or a group of fixtures, or make different address for 
each fixture individually. 
If you set the same address, all the units will start to “listen” to the same control signal from the same 
channel number. In other words, changing the settings of one channel will affect all the fixtures 
simultaneously. 
If you set a different address, each unit will start to “listen” to the channel number you have set, based on 
the quantity of control channels of the unit. That means changing the settings of one channel will affect only 
the selected fixture. 
 
In the case of the led lighting, which is 8 channels fixture when you select the standard channel mode, you 
should set the starting address of the first unit to 1, the second unit to 9(8 + 1), the third unit to 17 (8+ 9), 
and so on. 

 

 

Содержание Idea Par LED Zoom RGB

Страница 1: ...ONS 3 GENERAL GUIDELINES 4 INSTALLATION INSTRUCTIONS 5 Mounting the device 5 Overhead rigging 6 DMX 512 control connection Errore Il segnalibro non definito Control Board 8 Main functions 9 INSTRUCTIO...

Страница 2: ...ser manual from the Internet INTRODUCTION Thank you for having chosen this professional LED lighting You will see you have acquired a powerful and versatile device Unpack the device Inside the box you...

Страница 3: ...aler will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising cond...

Страница 4: ...professionals GENERAL GUIDELINES This device is a lighting effect for professional use on stages in discotheques theatres etc This fixture is only allowed to be operated with the max alternating curr...

Страница 5: ...ne technical installations are approved by an expert before taking the device into operation for the first time These installations have to be approved by a skilled person once a year CAUTION Before t...

Страница 6: ...control connection The product has a DMX 512 input fitted with standard 5 pin XLR connectors Screened cables in compliance with EIA RS 485 specifications and the following characteristics must be use...

Страница 7: ...MX starting address when using a DMX signal so that the correct fixture responds to the correct control signals This digital starting address is the channel number from which the fixture starts to lis...

Страница 8: ...sensitivity FAIL OFF HOLD AUTO SOUN No DMX Status REST Reset DFSE ON OFF Restore factory settings POHO ON OFF Power on to preserve the MANL settings 1 SET VER V 1 0 V 9 9 Software version 2 MANL RED...

Страница 9: ...this function you can define the device as slave 1 Select SLAV by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable this function or p...

Страница 10: ...rm the display shows D 00 In this setting the DMX adjustment of every channel will be displayed 3 Press UP or DOWN button in order to select the desired channel If you select D 12 the display will onl...

Страница 11: ...umber from 0 to 99 3 Press ENTER to confirm or Press MENU to return to the main menu Automatic Run by no DMX With this function you can automatic run the device by no DMX 1 Select FAIL by pressing UP...

Страница 12: ...Manual adjust intensity 1 Select MANL by pressing UP or DOWN button 2 Press ENTER the display shows RED GREN BLUE MACO PROG STRB DIMM ZOOM 3 Press UP or DOWN button to select RED GREN BLUE MACO PROG...

Страница 13: ...ion you can edit the program to be called up in Run a Editing via the Control Board 1 Select SC01 by pressing UP or DOWN button 2 Press ENTER the display shows SCXX X stands for the scene no to be edi...

Страница 14: ...ws FADE Adjust fade speed 6 Press ENTER the display to be adjust fade speed 7 Select CEDT by pressing UP or DOWN button 8 Press ENTER the display shows OFF 9 Press UP or DOWN button the display shows...

Страница 15: ...macro 6 48 55 Color macro 7 56 63 Color macro 8 64 71 Color macro 9 72 79 Color macro 10 80 87 Color macro 11 88 95 Color macro 12 96 103 Color macro 13 104 111 Color macro 14 112 119 Color macro 15...

Страница 16: ...ram 7 5 221 255 Gradient effect Shutter strobe 0 31 Led trun off 32 63 Led turn on 64 95 Strobe effect slow to fast 96 127 Led turn on 128 159 Pulse effect in sequences 160 191 Led turn on 192 223 Ran...

Страница 17: ...s on the housing fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power su...

Страница 18: ...sumption max 120 W Packing dimensions 40 x 30 x 48 CM Flight case dimensions 79x76 5x60 cm Net weight 7 KGS Gross weight 10KGS carton packing 75 5 KGS flight case packing 6pcs Remark errors and omissi...

Отзывы: