Standalone operation is not running when the fixture is connected to a control device, but when it is pre-programmed with a series of 

up to 24 scenes, playing continuously in a loop. Up to three stand-alone programs can be defined and run from the menus, and one of 

the programs can be set to run by default whenever the fixture is powered on.
Each of the three available standalone programs contains 24 user-definable 

scenes with its own RGB and shutter settings.
Each scene has a definable fade-in time for the transition from one color to the 

next, and a wait (static) time of up to 120 minutes and 59 seconds.
To define a stand-alone program, press ENTER → MANUAL → EDITOR.
The standalone mode of the fixture’s startup is enabled by selecting:

ENTER → SETTINGS → STARTUP MODE → SELECT STARTUP MODE → 

STANDALONE.
To select the fixture’s startup program, press:

ENTER → SETTINGS → STARTUP MODE → STARTUP PROGRAM.

The  chosen  program  will  run  its  length  cyclically  whenever  the  fixture  is       

powered on.
To run an internal program, go to:

ENTER → MANUAL → RUN PROGRAM.
To stop an active internal program, go to:

ENTER → MANUAL → STOP PROGRAM.
See “Control menu” on page 13-14 for detailed information about the manual menu. 

Please note: In POI versions, configuring the fixtures can only be done through RDM. 

Using standalone operation

Figure 11: Standalone operation

Most DMX channels: 

possibility to choose between raw or white-calibrated color (2000K - 10.000K) via the CTC channel. 

NOTE: when you adjust the white color temperature, all RGB or RGBW channels (if available) must be set to 100%.

RGB DMX modes:

 features full color calibration when you mix two or three colors to ensure uniform color between products. Ad-

justing one color does not activate full color calibration.
See all DMX protocols at www.sgmligh.com for more details.

Full Color Calibration and Color Temperature Correction (Q-2 RGBW only)

Setting a static color manually (Q-2 RGBW only)

The Q-2 can be configured to display a predefined and static color. 

To set up a static color select ENTER → MANUAL → QUICK COLOR.
Note that, once the MANUAL → QUICK COLOR settings are changed, the fixture will be set by default to automatically start in quick 

color mode whenever it is powered on. This can be reset through the menu SETTINGS → STARTUP MODE → SELECT STARTUP 

MODE. 
The current quick color program can always be stopped going to:

ENTER → MANUAL → STOP PROGRAM
See “Control menu” on pages 13-14 for detailed information about the manual menu. 

Please note: In POI versions, configuring the fixtures can only be done by RDM.

Содержание I-2 BLUE POI

Страница 1: ...USER MANUAL Q SERIES Q 2 POI Q 2 WHITE POI...

Страница 2: ...e without notice SGM and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability t...

Страница 3: ...for DMX control 10 Full Color Calibration and Color Temperature Correction Q 2 RGBW only 11 Setting a static color manually Q 2 RGBW only 11 Using standalone operation 11 Fixture properties 12 Q 2 Co...

Страница 4: ...height to prevent injury due to falls For Permanent Outdoor Installations POI ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For a t...

Страница 5: ...nt with the USITT DMX512 standard Very low power consumption 140W and an expected lifetime of the multiple LED s of 50 000 hours Optional accessories such as barndoors diffusion filters color frames e...

Страница 6: ...nly 1 x Mounting bracket with fasteners standard only 1 x Spanner with magnet POI only 2 x M 10 screws POI Only Safety information leaflet Location application The standard fixture is IP65 rated and i...

Страница 7: ...materials cables or surfaces to be illuminated within 0 3 m 12 in of the fixture 7 Check that there is no risk of the head yoke colliding with other fixtures or structures Q 2 Mounting bracket The sta...

Страница 8: ...ST in the menu to ensure that the fixture and each LED are functioning correctly POI versions have to be tested through RDM CAUTION Do not open the fixture to replace the supplied power cable Do not c...

Страница 9: ...n the fixture The adjustments are made through RDM See page 16 for more information The OLED display is the human interface of the fixture as it displays the current status and menu of the fixture The...

Страница 10: ...channel used to receive data from a DMX control device is known as the DMX start address For independent control each Q 2 must be assigned its own DMX start address For example if the first Q 2 is se...

Страница 11: ...n about the manual menu Please note In POI versions configuring the fixtures can only be done through RDM Using standalone operation Figure 11 Standalone operation Most DMX channels possibility to cho...

Страница 12: ...form adjustment throughout the control action whereas gamma corrected dimming provides finer control at low light levels where the eye is more sensitive to change By default the Q 2 uses gamma correct...

Страница 13: ...tory defaults on page 12 Service Pin Enter service pin to access service menu Service Menu Product Type Calibration Info PSU Voltage PWM Out MANUAL Quick Color Red 1 255 Set fixture to quick color sta...

Страница 14: ...uency Set the fixture to default frequency Custom Freq Use the arrows to select a custom frequency Minimum Values White 1 12 Set minimum values for individual LED panels Use the arrows to set the valu...

Страница 15: ...over a standard DMX line This protocol will allow configuration status monitoring and management A RDM controller is needed to get control over the supported parameters See the tables below for suppor...

Страница 16: ...ough RDM and using USB dongles disable the USB selective suspend to ensure a proper voltage on the DMX link If any lag or trouble occurs when addressing decrease the cable length range to 12 m and onl...

Страница 17: ...Q 2 POI has two M 10 nuts in the base that can be used for installation and rigging The SGM Omega bracket not included or a customized bracket is needed to install the fixture Consider the dimensions...

Страница 18: ...Disconnecting a wireless transmitter in POI To disconnect the Q 2 POI from the currently paired wireless transmitter simply hold the magnet for 3 seconds over the LED indicator The LED indicator blink...

Страница 19: ...lso compatible with the use of color frame and diffusion filters Floorstand The Q 2 Series has available an optional floorstand ideal when there is a frequent need of changing the position of the fixt...

Страница 20: ...is always up to date The latest firmware version is available for download under the respective product at www sgmlight com To update your Q 2 Series with the latest firmware use an SGM USB 5 Pin XLR...

Страница 21: ...P N 80030535 80030565 Q 2 Color Flood POI BL WH P N 80031000 80031050 Q 2 White Flood Std BL WH P N 80030536 80030567 The Q 2 Series can be ordered in any RAL color and can be customized into POI vers...

Страница 22: ...22 User Notes...

Страница 23: ...23 User Notes...

Страница 24: ...24 SGM Light A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Отзывы: