Connecting a wireless transmitter

The P-6 is designed to look for wireless transmitters in ‘connect’ state, when this option is not yet enabled.

To connect the P-6 to a wireless transmitter:

•  Log off the currently paired wireless transmitter - see below “Disconnecting a wireless transmitter”.

•  Press the connect button on the wireless transmitter.

•  Confirm that the fixture has paired with the wireless transmitter.

Disconnecting a wireless transmitter

To disconnect the fixture from the currently paired wireless transmitter, go to SETTINGS → WIRELESS DMX → LOG OFF.

Signal priority

The P-6 can be paired to an active wireless transmitter as soon as it is connected to a cabled DMX. The fixture will prioritize cabled 

DMX over wireless DMX. 
The active input type is displayed under the wireless signal strength indicator. The signal strength can also be checked via RDM data 

by using a external RDM device (e.g. the SGM A-4).

About DMX

The P-6 can be controlled using signals sent by a DMX controller on a number of DMX channels. DMX is the USITT DMX512-A 

standard, based on the RS-485 standard. The signal is sent as DMX data from a console or a controller, to the fixture(s) via a shielded 

twisted pair cable designed for RS-485 devices. 
The cables are daisy chained between the fixtures, and up to 32 fixtures can be connected on the same DMX link. Up to 300 meters 

(1000ft.) of cable is achievable with high quality DMX cables. All DMX links must be terminated in the last fixture by connecting a DMX 

termination plug to the last fixture´s 5 pin DMX out connector. 

PLEASE NOTE: 

•  Standard microphone cable is not suitable for transmitting DMX.

•  Up to 32 fixtures can be linked to the same DMX chain. Additional fixtures will overload the link.

•  The last fixture must always be fitted with a DMX termination plug to the fixture’s DMX out.

Set/edit DMX address

The DMX address is shown on the OLED display in the control panel. 

To change the address setting, press the up and down arrows. When the desired address is          

displayed, press ENTER to save the setting. 
For your convenience, the next available DMX address is displayed to the right.

See instructions on how to use the display panel in “Configuring the device” on page 8.
The P-6 also offers the option to set the DMX address through RDM. 

DMX modes

The P-6 operates in different modes. All DMX charts are available at www.sgmlight.com under the respective products, or upon       

request via [email protected].

Configuring the device for DMX control

DMX

8

6CH MODE

(7)

DMX address

Next 

available

DMX

Figure 8: Set/edit DMX address

Содержание 80031650

Страница 1: ...USER MANUAL P 6 Distributor www techni lux com Phone 407 857 8770 Fax 407 857 8771 Email sales techni lux com...

Страница 2: ...quential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this...

Страница 3: ...g the device 8 Connecting to a DMX control device 8 Configuring the device for DMX control 9 Using standalone operation 10 Setting a static color manually 11 Fixture properties 11 Control menu 12 RDM...

Страница 4: ...ING Take measures to prevent burns and fire Do not look directly at the light source from close range Take precautions when working at height to prevent injury due to falls For Permanent Outdoor Insta...

Страница 5: ...o 50C Fully adjustable CTC from 2 000K to 10 000K Built in wireless DMX and preset able standalone programs Fully RDM implemented Different beam angles available via magnetic easy fit holographic filt...

Страница 6: ...carry the fixture by connected cables or wires use the handle Preparing for installation The P 6 may be installed in any orientation and it might take up to 3 omega brackets per fixture Always use om...

Страница 7: ...C 120 F Steady state 59 C 138 F Tilt Lock Pitch angle indicator Connecting AC power The P 6 can operate on any 100 277 V 50 60 Hz AC mains power supply Connect the fixture to AC power using the suppli...

Страница 8: ...ure the Neutrik TRUE1 power in cable is properly connected To turn off the device simply disconnect the Neutrik TRUE1 power in cable When the fixture is powered on it boots and resets before displayin...

Страница 9: ...twisted pair cable designed for RS 485 devices The cables are daisy chained between the fixtures and up to 32 fixtures can be connected on the same DMX link Up to 300 meters 1000ft of cable is achiev...

Страница 10: ...75 W 100 277V AC 50 60 Hz 475 W 100 277V AC 50 60 Hz 475 W DMX Termination on last fixture DMX out DATA GND DATA DATA 120 Ohm 5 Max 6 units 16 A circuit P 6 P 6 P 6 Figure 9 P 6 connection diagram Sta...

Страница 11: ...inations for creative lighting designs Individual fixture settings Flipping the OLED display If the fixture is installed hanging upside down it might be useful to flip the display so that it is easier...

Страница 12: ...e Display Dim Dims the OLED display when the control panel is not in use Fan Mode Standard Adjust fan speed relative to internal fixture temperature Silent Low fan speed for quiet operation Max Power...

Страница 13: ...ubject to change without notice Sensors RDM enables various sensor readouts for remote device monitoring See the table below for sensors and sensor types Please note The RDM controller communicates wi...

Страница 14: ...he P 6 features various optional magnetic holographic filter frames Medium angle 19 Wide angle 45 Elliptical wide angle horizontal 63 x12 Elliptical wide angle vertical 12 x63 Empty filter frame for c...

Страница 15: ...eaturing 512 DMX channels for test purposes Cleaning SGM luminaires with IP66 rating do not need any cleaning procedures inside the fixture However cleaning the front lens may be needed to achieve the...

Страница 16: ...3061168 Filter frame Elliptical vert wide angle BL P 6 series P N 83061169 Filter frame Medium angle BL P 6 series P N 83061170 Filter frame Wide angle BL P 6 series P N 83061171 Filter frame without...

Страница 17: ..._ ________________________________________________________________________________________________________ _____________________________________________________________________________________________...

Страница 18: ...18 SGM Light A S Sommervej 23 8210 Aarhus V Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Отзывы: