12

Level 1

Level 2

Level 3

Function

Mode

Select Mode

-

Select DMX mode 

Info

Product Type

-

Displays product type

Firmware Version

-

Displays installed firmware version

Serial Number

-

Displays SGM serial#

RDM ID

-

Displays RDM ID. (Unique RDM ID for identification )

DMX View

Up to 504 DMX addresses

Displays received DMX levels

Temperatures

Mainboard

Displays

 fixture temperatures

LED Left
LED Right
Humidity head
Fan Left RPM
Fan Right RPM
Wireless signal
Wireless paired
Light pwn
Humidity base
Base

Power on time

Displays fixture total power on time

LED On Time

-

Displays LED total power on time. (R, G, B, W)

Errors

-

Displays error codes

Settings

Wireless DMX

Wireless log off 

Sends Log off command to the CRMX System

Signal strength

Displays strength of the wireless connection

Startup Mode

Select Startup Mode

Default operating mode when fixture is powered on:  1. DMX (factory default)  
                                                                                    2. Stand-alone 
                                                                                    3. Quick Color

Startup Program

Stand-alone program 1, 2 or 3. 
Only used if the startup mode is set  to “stand-alone”. Program 1 is default.

Flip Display

Disable

Selects normal control panel display.

Enable

Flips control panel display.

Display Saver

Display Off

Turns off the OLED display when the control panel is not in use.

Display Dim

Dims the OLED display when the control panel is not in use.

Fan Mode

Standard

Adjust fan speed relative to internal fixture temperature.

Silent

Low fan speed for quiet operation.

Max Power

High fan speed for maximum cooling effect.

Factory Default

-

Reset the fixture to factory default settings.

Manual

Quick Color

Red

Static quick color - red mix (0-255). Sets fixture to quick color startup mode.

Green

Static quick color - green mix (0-255). Sets fixture to quick color startup mode.

Blue

Static quick color - blue mix (0-255). Sets fixture to quick color startup mode.

Run Program

1, 2 or 3

Runs internal sequence 1,2 or 3.

Stop Program

-

Stops current running internal sequence or Quick Color.

Editor

Program

Currently selected program (1, 2 or 3).

Scene

Currently selected scene (1-24).

Red

Red value in currently selected scene (0-255).

Green

Green value in currently selected scene (0-255).

Blue

Blue value in currently selected scene (0-255).

Shutter

Shutter setting in currently selected scene (0-255). (According to latest DMX chart)

Fade Time (Min.)

Fade-in (transition) time to current scene in min. (0-511).

Fade Time (Sec.)

Fade-in (transition) time to current scene in sec. (0-59).

Wait Time (Min.)

Wait (static) time in current scene in min. (0-998).

Wait Time (Sec.)

Wait (static) time in current scene in sec. (0-59).

Test

Off

-

Stops test sequence execution.

Automated Test

-

Initiates a self-test sequence.

Display Test

-

Service use only.

Control menu

Содержание 80031650

Страница 1: ...USER MANUAL P 6 Distributor www techni lux com Phone 407 857 8770 Fax 407 857 8771 Email sales techni lux com...

Страница 2: ...quential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this...

Страница 3: ...g the device 8 Connecting to a DMX control device 8 Configuring the device for DMX control 9 Using standalone operation 10 Setting a static color manually 11 Fixture properties 11 Control menu 12 RDM...

Страница 4: ...ING Take measures to prevent burns and fire Do not look directly at the light source from close range Take precautions when working at height to prevent injury due to falls For Permanent Outdoor Insta...

Страница 5: ...o 50C Fully adjustable CTC from 2 000K to 10 000K Built in wireless DMX and preset able standalone programs Fully RDM implemented Different beam angles available via magnetic easy fit holographic filt...

Страница 6: ...carry the fixture by connected cables or wires use the handle Preparing for installation The P 6 may be installed in any orientation and it might take up to 3 omega brackets per fixture Always use om...

Страница 7: ...C 120 F Steady state 59 C 138 F Tilt Lock Pitch angle indicator Connecting AC power The P 6 can operate on any 100 277 V 50 60 Hz AC mains power supply Connect the fixture to AC power using the suppli...

Страница 8: ...ure the Neutrik TRUE1 power in cable is properly connected To turn off the device simply disconnect the Neutrik TRUE1 power in cable When the fixture is powered on it boots and resets before displayin...

Страница 9: ...twisted pair cable designed for RS 485 devices The cables are daisy chained between the fixtures and up to 32 fixtures can be connected on the same DMX link Up to 300 meters 1000ft of cable is achiev...

Страница 10: ...75 W 100 277V AC 50 60 Hz 475 W 100 277V AC 50 60 Hz 475 W DMX Termination on last fixture DMX out DATA GND DATA DATA 120 Ohm 5 Max 6 units 16 A circuit P 6 P 6 P 6 Figure 9 P 6 connection diagram Sta...

Страница 11: ...inations for creative lighting designs Individual fixture settings Flipping the OLED display If the fixture is installed hanging upside down it might be useful to flip the display so that it is easier...

Страница 12: ...e Display Dim Dims the OLED display when the control panel is not in use Fan Mode Standard Adjust fan speed relative to internal fixture temperature Silent Low fan speed for quiet operation Max Power...

Страница 13: ...ubject to change without notice Sensors RDM enables various sensor readouts for remote device monitoring See the table below for sensors and sensor types Please note The RDM controller communicates wi...

Страница 14: ...he P 6 features various optional magnetic holographic filter frames Medium angle 19 Wide angle 45 Elliptical wide angle horizontal 63 x12 Elliptical wide angle vertical 12 x63 Empty filter frame for c...

Страница 15: ...eaturing 512 DMX channels for test purposes Cleaning SGM luminaires with IP66 rating do not need any cleaning procedures inside the fixture However cleaning the front lens may be needed to achieve the...

Страница 16: ...3061168 Filter frame Elliptical vert wide angle BL P 6 series P N 83061169 Filter frame Medium angle BL P 6 series P N 83061170 Filter frame Wide angle BL P 6 series P N 83061171 Filter frame without...

Страница 17: ..._ ________________________________________________________________________________________________________ _____________________________________________________________________________________________...

Страница 18: ...18 SGM Light A S Sommervej 23 8210 Aarhus V Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Отзывы: